نتایج جستجو برای: thermoluminescent dosimetry

تعداد نتایج: 8409  

Journal: :Radiation protection dosimetry 2006
Linda V E Caldas Maria Inês Teixeira Gilberto M Ferraz

The dosimetric properties of sand from Brazilian beaches have shown to be useful for high-dose dosimetry. The thermoluminescent (TL) and electron paramagnetic resonance (EPR) techniques were utilised, and the sand samples were recently studied in relation to their main dosimetric properties. The EPR signal at g = 1.999 grows significantly in function of the absorbed dose, and the TL peaks appea...

Journal: :Radiation protection dosimetry 2006
C M S de Magalhães D N Souza L V E Caldas

The properties of the thermally stimulated exoelectron emission (TSEE) and thermoluminescent (TL) emission of topaz-glass composites were studied with the aim of using them as solid-state dosemeters. The TSEE response was studied as a function of radiation energy and as a function of absorbed dose. Topaz-glass composites presented a linear TL and TSEE response to dose within a range of 0.01-1 G...

Journal: :avicenna journal of dental research 0
ehsan hekmatian assistant professor, torabinejad dental research center, department of oral and maxillofacial radiology, school of dentistry, isfahan university of medical sciences, isfahan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (isfahan university of medical sciences) roshanak ghaffari assistant professor, department of oral and maxillofacial radiology, school of dentistry, islamic azad university khorasgan branch, isfahan, ir iranسازمان اصلی تایید شده: دانشگاه آزاد اسلامی علوم و تحقیقات (islamic azad university science and research branch) mohammad toghyani dentist, ir iran mitra karbasi kheir assistant professor, department of oral and maxillofacial radiology, school of dentistry, islamic azad university isfahan ( khorasgan branch), isfahan, ir iran; assistant professor, department of oral and maxillofacial radiology, school of dentistry, islamic azad university isfahan ( khorasgan branch), isfahan, ir iran. tel: +98-9134088924سازمان اصلی تایید شده: دانشگاه آزاد اسلامی علوم و تحقیقات (islamic azad university science and research branch)

conclusions there was no statistically significant difference in the parotid absorbed dose between spiral tomography and a panoramic radiograph (p value = 0.18). the overall results of this study were similar to other studies. results for the tube side parotid, the average absorbed doses in spiral tomography of the anterior and posterior parts of the maxilla and mandible, with the 2 mm slice th...

2005
ERIC C. MARTIN

Thermoluminescent dosimetry was used to measure the radiation exposure to the skin, thyroid and gonads in 50 consecutive pediatric patients undergoing cardiac catheterization and angiocardiography using cine photofluorography. Average exposures were 17.1 R to the skin, 2.3 R to the thyroid and 0.1 R to the gonads. Fluoroscopy accounted for approximately 80% of the skin and thyroid exposure and ...

Journal: :Interfaces 2004
Murat Bayiz Christopher S. Tang

ABC Worldwide Dosimetry Service provides a high-quality service for measuring and reporting radioactive exposure at its customers’ sites. It leases thermoluminescent badges that record radioactive exposure over a prespecified time period. As each recording cycle ends, ABC must send refurbished (or new) badges to the customers before they return the old badges to ensure continuous monitoring. It...

Journal: :Circulation 1981
E C Martin A P Olson C N Steeg W J Casarella

Thermoluminescent dosimetry was used to measure the radiation exposure to the skin, thyroid and gonads in 50 consecutive pediatric patients undergoing cardiac catheterization and angiocardiography using cine photofluorography. Average exposures were 17.1 R to the skin, 2.3 R to the thyroid and 0.1 R to the gonads. Fluoroscopy accounted for approximately 80% of the skin and thyroid exposure and ...

2001
Christopher T. Baird George Starkschall H. Helen Liu Thomas A. Buchholz Kenneth R. Hogstrom

The accuracy of the photon convolution/superposition dose algorithm employed in a commercial radiation treatment planning system was evaluated for conditions simulating tangential breast treatment. A breast phantom was fabricated from machineable wax and placed on the chest wall of an anthropomorphic phantom. Radiographic film was used to measure the dose distribution at the axial midplane of t...

2010
Mei-Kang Yuan Ching-Wen Chien San-Kan Lee Nai-Wei Hsu Shih-Chieh Chang Shu-Ju Chang Gau-Jun Tang

Medical application of radiation began a few months after the discovery of X-rays by the German physicist Wilhelm Conrad Röntgen more than 100 years ago. The harmful biological effects of ionizing radiation became apparent shortly after its utilization. Since 1920, health professionals in contact with radiation have worn lead protective clothing to reduce the harmful effects of ionizing radiati...

2005
Sharifeh A. Dini Rafiq A. Koona John R. Ashburn Ali S. Meigooni

The high spatial resolution of radiochromic film makes it ideal for dosimetric measurements and dose distributions in regions of high dose gradient. Intensity-modulated radiation therapy, intravascular brachytherapy, and eye-plaque radiation therapy demand precise spatial dosimetric calculations. Such precision is not possible with conventional dosimeters, such as thermoluminescent dosimeters a...

2009
C. Cosma Alida Timar V. Benea T. Jurcut D. Ciorba

The main trend in radiation dosimetry nowadays is the use of solid state detectors. Luminescent dosimetric techniques are part of this field. This paper aims to present the application of thermoluminescence as a tool in measuring natural nuclear radiation, namely the application of highly sensitive sintered dosimeters MCP-N (LiF:Mg,Cu,P) in environmental monitoring and the possibility of using ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید