نتایج جستجو برای: treatment planning system tps

تعداد نتایج: 3600267  

2016
Gangarapu Sri Krishna Vuppu Srinivas K. M. Ayyangar Palreddy Yadagiri Reddy

Recently, Eclipse treatment planning system (TPS) version 8.8 was upgraded to the latest version 13.6. It is customary that the vendor gives training on how to upgrade the existing software to the new version. However, the customer is provided less inner details about changes in the new software version. According to manufacturer, accuracy of point dose calculations and irregular treatment plan...

2009
E. M. Simão L. E. A. Macedo D. N. Souza

Radiation oncology requires appropriate planning of both target volume and location. The correct calculation of the target volume as well as the precise location of critical anatomic structures is vitally important to ensure the success of treatment. Treatment planning systems (TPS) are used in radiation teletherapy to simulate the projection of the field, its shape and the distribution of the ...

2012
Parham Alaei Emiliano Spezi

The feasibility of accounting of the dose from kilovoltage cone-beam CT in treatment planning has been discussed previously for a single cone-beam CT (CBCT) beam from one manufacturer. Modeling the beams and computing the dose from the full set of beams produced by a kilovoltage cone-beam CT system requires extensive beam data collection and verification, and is the purpose of this work. The be...

Journal: :journal of biomedical physics and engineering 0
s sina radiation research center, shiraz university, shiraz, iran r faghihi a s meigooni

background: most of the current brachytherapy treatment planning systems (tps) use the tg-43u1 recommendations for dosimetry in water phantom, not considering the heterogeneity effects. objective: the purpose of this study is developing a method for obtaining correction factors for heterogeneity for cs-137 brachytherapy sources based on pre-calculated mc simulations and interpolation. method: t...

2016
Bagher Farhood Mohammad Taghi Bahreyni Toossi Shokouhozaman Soleymanifard

Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective ...

2015
M. DUMITRACHE Alina TĂNASE

The purpose of this work was to perform a comprehensive comparison of static field intensity modulated radiation therapy (IMRT) for patient specific quality assurance (QA) in order to investigate commissioning of a XiO treatment planning system (TPS). QA measurements were evaluated for three of four test geometries provided in American Association of Physicists in Medicine (AAPM) Task Group Rep...

2017
Dustin J. Jacqmin Jeremy S. Bredfeldt Sean P. Frigo Jennifer B. Smilowitz

The AAPM Medical Physics Practice Guideline (MPPG) 5.a provides concise guidance on the commissioning and QA of beam modeling and dose calculation in radiotherapy treatment planning systems. This work discusses the implementation of the validation testing recommended in MPPG 5.a at two institutions. The two institutions worked collaboratively to create a common set of treatment fields and analy...

Background: The Monte Carlo (MC) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (TPS) calculations. Materials and Methods: Three 60Co sources of GZP6 brachytherapy unit were simulated using MCNP4C MC Code. The radial dose functions were calculated by MC method and GZP6 TPS and were compared. Results: There was a go...

Journal: :iranian journal of radiation research 0
s. senthilkumar department of radiotherapy, madurai medical college and govt. rajaji hospital, maduari-625 020, india

background: the purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the treatment planning systems (tps) calculated values for different lung treatment dosimetery. it is compared with thermoluminescent dosimeter (tld) measurement. materials and methods: homogeneous and heterogeneous tho...

2015
Sarah J. Alnaghy Shrikant Deshpande Dean L. Cutajar Kemal Berk Peter Metcalfe Anatoly B. Rosenfeld

Verification of dose to the anterior rectal wall in helical tomotherapy to the prostate is important due to the close proximity of the rectal wall to the treatment field. The steep dose gradient makes these measurements challenging. A phantom-based study was completed, aimed at developing a system for measurement of anterior rectal wall doses during hypofractionated prostate stereotactic body r...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید