An experimental thermal survey of a turbocharger was performed in an engine test cell using IR thermography. The emissivity coefficients housings were specified furnace and camera. It shown that the turbine, compressor, bearing are 0.92, 0.65, 0.74, respectively. In addition, thermocouples mounted on housing to validate temperature camera while running cell. To compare data thermocouple with fr...