Linear AC power supplies can be replaced by their nonlinear switching counterparts due to the lower voltage drops and higher efficiency and power density of switching-mode inverters. Multilevel cascaded H-bridge (CHB) converters are the preferred inverter structure because of modular configuration, control, and protection. The output voltage quality in CHB converters depends on the number of ou...
Most of the losses in a power system relate to the distribution sector which always has been considered. From the important factors which contribute to increase losses in the distribution system is the existence of radioactive flows. The most common way to compensate the radioactive power in the system is the power to use parallel capacitors. In addition to reducing the losses, the advantages o...
We explored the energy loss mechanisms in capacitive deionization (CDI). We hypothesize that resistive and parasitic losses are two main sources of energy losses. We measured contribution from each loss mechanism in water desalination with constant current (CC) charge/discharge cycling. Resistive energy loss is expected to dominate in high current charging cases, as it increases approximately l...
Optimal reconfiguration and capacitor placement are used to reduce power losses and keep the voltage within its allowable interval in power distribution systems considering voltage, current, and radial condition constraints. It is needed to solve two nonlinear discrete optimization problems simultaneously, so an intelligent algorithm is used to reach an optimum solution for network power losses...
To provide the required service quality to the consumers connected to the ending buses of radial distribution feeders, the voltage magnitude is set at higher values at the substation point and hence, at the buses located within the beginning feeder sections. The active and reactive powers are in touch with voltage magnitude at the corresponding buses. Accordingly, the voltage increase stimulate...
Transformerless topologies are widely preferred to use in the grid connected photovoltaic (PV) generation system due to higher efficiency, lower cost and lower weight in comparison with other topologies employing transformer. In this paper, switching losses is minimized by incorporating Zero Voltage Switching (ZVS) in a full-bridge topology, at switch turn-on and an adaptive Variable dead-time ...