The objective of this study was to investigate the cooling performance characteristics of an electrical air conditioning system using R744 as an alternative of R-134a for a fuel cell electric vehicle. In order to analyze the cooling performance characteristics of the air conditioning system using R744 for a fuel cell electric vehicle, an electrical air conditioning system using R744 was develop...
چرخه در هنگام طلوع آفتاب شروع می شود. نقطه a در شکل زمانی است که که کلکتور خورشیدی در دمای محیط ta و حداکثر غلظت ممکن از مبرد موجود در مواد جاذب است. گرمایش خورشیدی کلکتور از نقطه a به b، موجب افزایش فشار از pe به pc می شود، (جرم جذب شده همچنان ثابت است). در این فشار گاز مبرد شروع به آزاد شدن می کند و فشار تقریبا ثابت و معادل pc می ماند (فشار چگالش) . دمای جاذب تا دمای حداکثر چرخه، tg در نقطه d...
This paper deals with the investigation of substitutes for R-22 and their heat transfer behaviour in a plate-type evaporator with a falling water film as heat source. Alternatives investigated were R-134a and two new refrigerant mixtures. Measurements on a 3m x 0,5m plate showed a superior performance ofR-134a compared to R-22 and mixtures at equal test conditions and a distinct difference betw...
Heat transfer and fluid flow in spray evaporators with application to reducing refrigerant inventory
As the phase-out of chlorofluorocarbons (CFC's) approaches, there is a current need for the development of new vapor compression chillers which can operate with non-CFC refrigerants while still maintaining high operating efficiencies. Redesign of the traditional flooded evaporator used in refrigeration chillers so as to incorporate a spray evaporation capability offers both a potential for incr...
The objective of this study was to investigate the stability and aerosolization of pressurized metered dose inhalers (pMDIs) containing thymopentin nanoparticles. Thymopentin nanoparticles, fabricated by a bottom-up process, were suspended in hydrofluoroalkane (HFA) 134a together with cineole and/or n-heptane to produce pMDI formulations. The stability study of the pMDIs obtained was carried ou...
the pressure drop of refrigerant r-134a flow boiling inside a horizontal tube has been investigated experimentally. the test set-up which was used in this investigation is a well instrumented vapor compression refrigeration system. these instruments are thermocouples, flow meter, pressure gauges and the pressure drop measuring apparatus. this system consisted of three electrically heated evapor...
Flow boiling heat transfer with the refrigerants R-134a and R-245fa in copper microchannel cold plate evaporators is investigated. Arrays of microchannels of hydraulic diameter 1.09 mm and 0.54 mm are considered. The aspect ratio of the rectangular cross section of the channels in both test sections is 2.5. The heat transfer coefficient is measured as a function of local thermodynamic vapor qua...
Measurements of two-phase flow pressure drop have been made during a phase-change heat transfer process with refrigerant (R-134a) as a working fluid for a wide range of pressures right up to the critical pressure. The experiments were conducted in a uniformly heated vertical tube of 12.7 mm internal diameter and 3 m length over a heat flux range of 35–80 kW/m, mass flux range of 1200–2000 kg/m ...