PURPOSE To evaluate the contrast sensitivity and stereopsis tests in patients who underwent bilateral implantation of multifocal intraocular lens. METHODS Tests of contrast sensitivity using the Pelli-Robson chart and stereopsis evaluation with the Titmus Stereo Test were performed in 20 patients 30-60 days after the bilateral implantation of Acrysof Restor multifocal intraocular lens. RESU...
AIM To determine a suitable intraocular lens for implantation in patients at high risk of lens exposure to silicone oil in their lifetime. METHODS PMMA, AcrySof, AR40, AQUA-Sense, and Raysoft lenses were examined. Each lens was immersed for 5 minute intervals in balanced salt solution (BSS), in stained silicone oil, and again in BSS before being photographed in air and in BSS. Percentage sili...
OBJECTIVES To evaluate success rates in the correction of astigmatism with toric and spherical soft contact lens fitting. METHODS 30 patients with soft toric lenses having more than 1.25 D of corneal astigmatism (25 eyes; Group A) or having 0.75-1.25 D of corneal astigmatism (22 eyes; Group B) and 30 patients with soft spheric lenses having 0.75-1.25 D of corneal astigmatism (28 eyes; Group C...
PURPOSE To describe a novel technique for toric intraocular lens (IOL) repositioning and fixation in the absence of adequate capsular support. METHODS Case report and literature review. RESULTS Two cases are presented with scleral fixation of a one-piece toric IOL (SN6AT series; Alcon Laboratories, Inc., Fort Worth, TX). In both cases, toric IOLs initially placed within the capsular bag bec...
Purpose To compare two calculators for toric intraocular lens (IOL) calculation and to evaluate the prediction of refractive outcome. Methods Sixty-four eyes of forty-five patients underwent cataract surgery followed by implantation of a toric intraocular lens (Zeiss Torbi 709 M) calculated by a standard industry calculator using front keratometry values. Prediction error, median absolute err...
Obviously, toric lenses have to remain in stable positions after implantation bearing in mind that for every 10 degrees of misalignment, there is one third loss of toric correction. While some time ago this was still a problem, toric IOLs of today are significantly less affected by lens rotation. Another disturbing issue with toric lenses has also been fixed in the meantime: according to a new ...
PURPOSE To evaluate the in vivo aberrometric performance of two phakic intraocular lenses (PIOLs); the Visian implantable contact lens (ICL) and the AcrySof Cachet PIOL. METHODS Thirty eight eyes from 29 patients with an age range of 23-32 years and more than 9 D of myopia were divided into two groups; one group of 20 eyes received a Visian ICL model V4c, another group of 18 eyes received an ...
PURPOSE To evaluate efficacy, predictability, and safety of Artisan toric phakic intraocular lens (Ophtec, Groningen, The Netherlands) implantation for the correction of astigmatism higher than 2 diopters. DESIGN Interventional case series. METHODS This prospective study included 27 eyes of 16 patients with a mean preoperative spherical equivalent of -11.78 +/- 6.24 diopters and a mean preo...