نتایج جستجو برای: axial load

تعداد نتایج: 192926  

2008
Yoon-Ho Ahn Wen-Ming Chen Kwon-Yong Lee Kyung-Woo Park Sung-Jae Lee

Recently, numerous types of posterior dynamic stabilization (PDS) devices have been introduced as an alternative to the fusion devices for the surgical treatment of degenerative lumbar spine. It is hypothesized that the use of ‘compliant’ materials such as Nitinol (Ni–Ti alloy, elastic modulus = 75 GPa) or polyether-etherketone (PEEK, elastic modulus = 3.2 GPa) in PDS can restore stability of t...

2003
N. C. PERKINS

In the referenced paper [ 11, the author examines the stability of the planar, linear response of a suspended cable subjected to harmonic axial loading. The study is motivated by a desire to understand the dynamic stability of cables employed in structures such as cablestayed bridges or guy-towers. In these applications, the harmonic axial load derives from the dynamic reaction of the structure...

Journal: :Traffic injury prevention 2013
D E Toomey K H Yang N Yoganandan F A Pintar C A Van Ee

OBJECTIVE The compressive tolerance of the cervical spine has traditionally been reported in terms of axial force at failure. Previous studies suggest that axial compressive force at failure is particularly sensitive to the alignment of the cervical vertebra and the end conditions of the test methodology used. The present study was designed to develop a methodology to combine the data of previo...

Journal: :Applied Mathematical Modelling 2021

For the first time, structural dynamics and vibrational stability of a viscoelastic axially functionally graded (AFG) beam with both spinning axial motions subjected to an load are analyzed, aim enhance performance bi-gyroscopic systems. A detailed parametric study is also performed emphasize influence various key factors such as material distribution type, viscosity coefficient, coupled rotati...

Journal: :مهندسی منابع معدنی و هیدروکربنی 0
سیامک دوستداری . راحب باقرپور . علیرضا باغبانان .

tehran shomal highway passes through alborz mountains with a tunnel length of 6400 meters. there are two main tunnels. a full three-dimensional (3d) numerical analysis coupled with elasto-plastic material models was conducted on the inclined access tunnel. bending moment, axial force and the lining displacements due to the internal forces applied on the shotcrete lining are calculated. axial fo...

2012
X. Zeng B. Xu

In this study, experimental study on six RC columns with different slenderness ratios under axial rapid loading was conducted to investigate the axial compression behaviour of RC columns considering the effect of strain rates. The failure pattern of the specimens and the relations of axial loading versus the axial deformation were described. From the test results, the specimens under static and...

Journal: :American journal of physiology. Heart and circulatory physiology 2006
Devinder Rehal Xiaomei Guo Xiao Lu Ghassan S Kassab

The zero-stress state of a blood vessel has been extensively studied because it is the reference state for which all calculations of intramural stress and strain must be based. It has also been found to reflect nonuniformity in growth and remodeling in response to chemical or physical changes. The zero-stress state can be characterized by an opening angle, defined as the angle subtended by two ...

2012
Susan K. Grimston Marcus P. Watkins Michael D. Brodt Matthew J. Silva Roberto Civitelli

The gap junction protein, connexin43 (Cx43) is involved in mechanotransduction in bone. Recent studies using in vivo models of conditional Cx43 gene (Gja1) deletion in the osteogenic linage have generated inconsistent results, with Gja1 ablation resulting in either attenuated or enhanced response to mechanical load, depending upon the skeletal site examined or the type of load applied. To gain ...

2014
Kota Watanabe Tomoaki Kamiya Daisuke Suzuki Hidenori Otsubo Atsushi Teramoto Tomoyuki Suzuki Toshihiko Yamashita

Introduction: Recently, new plates with locking screws have been developed and used for medial open-wedge high tibial osteotomy (HTO). The purpose of this study was to evaluate and compare biomechanical properties of different internal fixations in open-wedge HTO using the two currently available locking plates. Methods: Eight paired fresh-frozen cadaveric lower extremities were vertically embe...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید