نتایج جستجو برای: block pulse function

تعداد نتایج: 1429497  

Journal: :Molecular pharmacology 2003
Andrei Kondratiev Gordon F Tomaselli

The cytoplasmic side of the voltage-dependent Na+ channel pore is putatively formed by the S6 segments of domains I to IV. The role of amino acid residues of I-S6 and II-S6 in channel gating and local anesthetic (LA) block was investigated using the cysteine scanning mutagenesis of the rat skeletal muscle Na+ channel (Nav1.4). G428C uniquely reduced sensitivity to rested state or first-pulse bl...

Journal: :The journal of physical chemistry letters 2012
Louise Belshaw Francesca Calegari Martin J Duffy Andrea Trabattoni Luca Poletto Mauro Nisoli Jason B Greenwood

We present the first direct measurement of ultrafast charge migration in a biomolecular building block - the amino acid phenylalanine. Using an extreme ultraviolet pulse of 1.5 fs duration to ionize molecules isolated in the gas phase, the location of the resulting hole was probed by a 6 fs visible/near-infrared pulse. By measuring the yield of a doubly charged ion as a function of the delay be...

Journal: :Circulation research 1988
C W Clarkson C H Follmer R E Ten Eick L M Hondeghem J Z Yeh

The effects of lidocaine on sodium current in cardiac myocytes isolated from cat and guinea pig were investigated using the whole-cell variation of the patch-clamp technique. Lidocaine (43-200 microM) reduced sodium current during repetitive depolarizing pulses in a use-dependent manner. To clarify the nature of the use-dependent block, we characterized the time course of block development usin...

Journal: :Computer-aided Civil and Infrastructure Engineering 2023

A novel multibody rocking model is developed to investigate the dynamic response of two stacked rigid blocks placed on a linear base isolation device. The used realistic statue-pedestal system subject pulse-like ground motions. analysis shows that, in general, increases safety level system. However, for large period pulses or small size blocks, isolator can amplify motion, resulting lower minim...

Journal: :نشریه دانشکده فنی 0
مصطفی فاطمی

pulse echo b - scan imaging systems have been used for years in medical diagnosis. the theroy of such systems have been investigated by several researchers. in this paper, we introduce a new model for b - scan imaging system based on gaussian type transducer. an imaging system is normally identified by its point response function. this function describes the image of a single physical point obj...

Journal: :Monthly Notices of the Royal Astronomical Society 2016

Journal: :Fractal and fractional 2022

In this paper, we solve Riccati equations by using the fractional-order hybrid function of block-pulse functions and Bernoulli polynomials (FOHBPB), obtained replacing x with xα, positive α. Fractional derivatives are in Caputo sense. With help incomplete beta functions, able to build exactly Riemann–Liouville fractional integral operator associated FOHBPB. This operator, together Newton–Cotes ...

Journal: :Transactions of the Society of Instrument and Control Engineers 1988

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید