نتایج جستجو برای: chemiluminescence method

تعداد نتایج: 1634362  

Journal: :The Biochemical journal 1985
S Birman

A chemiluminescence method for determining acetylcholinesterase activity is described. It is an adaptation of the chemiluminescence assay of acetylcholine described by Israël & Lesbats [(1981) Neurochem. Int. 3, 81-90; (1981) J. Neurochem. 37, 1475-1483]. The acetylcholinesterase activity is measured by monitoring the increase in light emission produced by the accumulation of choline or by dete...

Journal: :Analytica chimica acta 2012
M Catalá-Icardo J L López-Paz C Choves-Barón A Peña-Bádena

The determination of dimethoate using either its native chemiluminescent (CL) properties or its photoinduced chemiluminescence obtained by irradiation with a 15 W low-pressure mercury lamp was studied. Thereby, two flow injection systems (FIA) with and without irradiation were exhaustively optimized and their analytical characteristics studied. Better sensitivity and selectivity was found in ab...

Journal: :Journal of the Spectroscopical Society of Japan 1974

Journal: :The Biochemical journal 1980
E Cadenas A Boveris B Chance

Submitochondrial particles from bovine heart mitochondria showed low-level chemiluminescence when supplemented with organic hydroperoxides. Chemiluminescence seems to measure integratively radical reactions involved in lipid peroxidation and related processes. Maximal light-emission was about 1500 counts/s and was reached 2-10min after addition of hydroperoxides. Ethyl hydroperoxide, cumene hyd...

Journal: :Mediators of Inflammation 1998
G Sadeghi-Hashjin P A Henricks G Folkerts T Muis J Garssen F P Nijkamp

The lucigenin-dependent chemiluminescence generation by guinea-pig isolated tracheal two rings preparations was studied. Tracheal preparations stimulated with phorbol myristate acetate (PMA) or opsonized zymosan generated chemiluminescence. The total amount of chemiluminescence generated in 120 min was 754+/-63 mV x min for PMA and 4832+/-396 mV x min for zymosan. Generation of chemiluminescenc...

Journal: :Journal of clinical microbiology 2015
Victoria González Gema Fernández Eva Dopico Nuria Margall Juliana Esperalba Carme Muñoz Elisabeth Castro Elena Sulleiro Lurdes Matas

We report here the results of the diagnostic performances of Vitros Syphilis TPA (a chemiluminescence treponemal assay) compared with those of two treponemal enzyme immunoassays and of traditional versus reverse syphilis algorithms. Ease of use, automation, and high throughput make the Vitros Syphilis TPA assay a good choice for syphilis screening in high-volume laboratories.

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2009
Aiping Fan Zhijuan Cao Huan Li Masaaki Kai Jianzhong Lu

Chemiluminescent (CL) detection techniques for DNA assays and immunoassays have become very popular in recent years. This review discusses recent advances in those CL assays that have occurred over the last few years. In the monoplex assay section, different classes of CL labels including nanoparticle, DNAzyme, acridinium ester, enzyme and luminol-based CL assays are reviewed concerning the det...

2015
Navoda Atapattu Subashini Jayasena Eresha Jasinghe Dayanath Bolonnage Shamya De Silva

Method The study was conducted in the largest children’s hospital in Sri Lanka. The children with radiological rickets were included in the study. Patients with chronic renal failure and liver failure were excluded. The study was conducted from 2012 June to 2014 June. Data obtained from the department of chemical Pathology Lady Ridgeway Hospital Sri Lanka. Vitamin D level was measured using Che...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید