نتایج جستجو برای: ctdivol

تعداد نتایج: 129  

Journal: :Medical physics 2017
Francesco Ria Joshua Mark Wilson Yakun Zhang Ehsan Samei

PURPOSE Modern CT systems adjust X-ray flux accommodating for patient size to achieve certain image noise values. The effectiveness of this adaptation is an important aspect of CT performance and should ideally be characterized in the context of real patient cases. The objective of this study was to characterize CT performance with a new metric that includes image noise and radiation dose acros...

2018
Paolo De Marco Daniela Origgi

PURPOSE To assess the noise characteristics of the new adaptive statistical iterative reconstruction (ASiR-V) in comparison to ASiR. METHODS A water phantom was acquired with common clinical scanning parameters, at five different levels of CTDIvol . Images were reconstructed with different kernels (STD, SOFT, and BONE), different IR levels (40%, 60%, and 100%) and different slice thickness (S...

Journal: :Iranian Journal of Radiology 2023

Background: With the development of computed tomography (CT) technology, number infants undergoing CT examination has increased. Recently, problems associated with radiation exposure have attracted public attention, and low-dose become research focus. Objectives: This study aimed to explore feasibility a fixed ultralow tube current combined iDose4 iterative reconstruction at low voltage (80 kV)...

Journal: :Egyptian Journal of Radiology and Nuclear Medicine 2021

Abstract Background While the second wave of COVID-19 pandemic almost reached its climax, unfortunately, new viral strains are rapidly spreading, and numbers infected young adults rising. Consequently, chest high-resolution computed tomography (HRCT) demands increasing, regarding patients’ screening, initial evaluation follow up. This study aims to evaluate detection accuracy ultra-low-dose CT ...

2017
Robert Chrzan Artur Jurczyszyn Andrzej Urbanik

BACKGROUND For decades, the main imaging tool in multiple myeloma (MM) patients was plain radiography. However, computed tomography (CT) has been included in the updated criteria of MM. The main disadvantage of CT is a considerably high radiation dose. Therefore, low-dose CT protocols could be a solution. The aim of the study was to (1) preliminarily analyse the usefulness of Whole-Body Low-Dos...

2013
Zhiwei Huang Bo Xiao Lisha Zhong

Objective: On the premise that the image quality meets the requirements of clinical diagnosis, we explored the methods to reduce the radiation dose of coronary artery imaging with Dual-Source CT (DSCT). Methods: We randomly selected 200 patients with coronary heat disease (BIM<25kg/m2), applied the scanning technology of regulating the dose of heart electric pulse (AUTO) on the 100 patients in ...

2018
Sebastian Ehn Thorsten Sellerer Daniela Muenzel Alexander A. Fingerle Felix Kopp Manuela Duda Kai Mei Bernhard Renger Julia Herzen Julia Dangelmaier Benedikt J. Schwaiger Andreas Sauter Isabelle Riederer Martin Renz Rickmer Braren Ernst J. Rummeny Franz Pfeiffer Peter B. Noël

The performance of a recently introduced spectral computed tomography system based on a dual-layer detector has been investigated. A semi-anthropomorphic abdomen phantom for CT performance evaluation was imaged on the dual-layer spectral CT at different radiation exposure levels (CTDIvol of 10 mGy, 20 mGy and 30 mGy). The phantom was equipped with specific low-contrast and tissue-equivalent ins...

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

2016
Thomas Henzler Nils Vogler Bettina Lange Franz Dally Mathias Meyer Stefan O. Schoenberg Maliha Sadick

OBJECTIVES To prospectively evaluate the diagnostic value and radiation dose of time-resolved CT-Angiography (4D-CTA) in pediatric patients with venous malformations using 3rd generation dual-source CT (DSCT) at 70 kVp tube voltage. METHODS Between November 2014 and August 2015, seven children (2 male, 5 female; median age, 9 years; range 3-12 years) with suspected peripheral, non-cerebral, v...

2016
S. Gharbi S. Labidi M. Chelli F. Ladeb

The purpose of this study is to reduce radiation dose for chest CT examination by including Tube Current Modulation (TCM) to a standard CT protocol. A scan of an anthropomorphic male Alderson phantom was performed on a 128-slice scanner. The estimation of effective dose (ED) in both scans with and without mAs modulation was done via multiplication of Dose Length Product (DLP) to a conversion fa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید