نتایج جستجو برای: differential transformer

تعداد نتایج: 295999  

2012
Hwa Chang Chang - Hung Hsu

This study reports the preparation of soft magnetic ribbons of Fe-based amorphous alloys using the single-roller melt-spinning technique. Ribbon width varied from 142 mm to 213 mm and, with a thickness of approximately 22 μm 2 μm. The microstructure and magnetic properties of the ribbons were characterized by differential scanning calorimeter (DSC), X-ray diffraction (XRD), vibrating sample mag...

The aim of this paper is to extend a hybrid protection plan for Power Transformer (PT) based on MRA-KSIR-SSVM. This paper offers a new scheme for protection of power transformers to distinguish internal faults from inrush currents. Some significant characteristics of differential currents in the real PT operating circumstances are extracted. In this paper, Multi Resolution Analysis (MRA) is use...

Journal: :Journal of the Japan Society for Precision Engineering 1990

2009
Sy-Ruen Huang Chin-Wen Liao Hong-Tai Chen Chueh-Cheng Wu C.-C. WU

This paper proposes a new method to detect transformer inside incipient fault current using transformer internal parameters to determine the inside structure of transformer at good condition or bad. A transformer model was established by Jiles– Atherton theory using measured voltage and current and the initial parameters which were found using Genetic Algorithm (GA). Then, transformer internal ...

2014
Geetha Mani

In transformer fault diagnosis, dissolved gas analysis (DGA) is been widely employed for a long period and numerous methods have been innovated to interpret its results. Still in some cases it fails to identify the corresponding faults. Due to the limitation of training data and non-linearity, the estimation of key-gas ratio in the transformer oil becomes more complicated. This paper presents I...

جلیلیان, علیرضا , عبداللهی, روح اله ,

In this paper, a 24-pulse ac-dc converter is designed, modeled and simulated based on a fork autotransformer to improve power quality indices. The use of autotransformer results in reduced kVA rating of the proposed topology as compared with the transformer based 24-pulse converter. Due to the proper flexibility of the proposed topology, it can be simply utilized in other similar applications. ...

Journal: :journal of artificial intelligence in electrical engineering 0

in this article, a multi-objective function for placement of distributed generation (dg) and capacitors with thetap setting of under load tap changer (ultc) transformer is introduced. most of the recent articles have paidless attention to dg, capacitor placement and ultc effects in the distribution network simultaneously. insimulations, a comparison between different modes was carried out with,...

2006
Zhang Weizheng Li Yanming Yang Lanjun

This paper presents the general knowledge, theory and methodology of life management that used in electric power transformer. The paper also discusses the basic failure theory and method to establish failure model of power transformer. Insulation ageing is a problem due to dielectric, chemical, thermal and electro-mechanic stresses, which is highly depending on operational conditions. Life mana...

2006
N. A. Muhamad S. A. M. Ali

Condition monitoring of electrical power equipment has attracted considerable attention for many years. The aim of this paper is to use Labview with Fuzzy Logic controller to build a simulation system to diagnose transformer faults and monitor its condition. The front panel of the system was designed using LabVIEW to enable computer to act as customer-designed instrument. The dissolved gas-in-o...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید