نتایج جستجو برای: dose rate

تعداد نتایج: 1226890  

Journal: :International Journal of Radiation Oncology*Biology*Physics 2019

A. Bozkurt, G. Kemikler, H. Acun,

Background: This study aims to calculate the air-kerma strength (SK), the dose rate constant (∧) and the dose rate profiles of a Gammamed 12i Ir-192 source by using the Monte Carlo technique and to compare the dose rate values with those calculated by the Abacus HDR treatment planning system (TPS). Materials and Methods: Air-kerma strength (in units of U; 1 U= μGy m2 h-1) and the dose ra...

Journal: :iranian journal of medical physics 0
vahid lohrabian educational development center, ilam university of medical sciences, ilam, iran

introduction low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. dosimetric characteristics of a new irseed 125i brachytherapy source have been determined using the lif thermoluminescent dosimeter (tld) chips. materials and methods dose rate constant, radial dose function, and anisotropy function around the irseed 125i so...

2013
Krystyna Serkies Adam Ziemlewski Tomasz Sawicki Joanna Kamińska Rafał Dziadziuszko

PURPOSE PURPOSE To present our experience with pulsed dose rate brachytherapy (PDR BT) of lip cancer. MATERIAL AND METHODS The study group included 32 T1-4N0M0 lip cancer patients with a median age of 71 years (ranged 41-87 years), treated with interstitial PDR BT to the planned total dose of 60-70 Gy; 1 Gy/pulse, pulses repeated every hour a day. There were 26 untreated patients, and six ...

1995
Michael C. Maher

Associated with this gamma dot environment is dose rate upset threshold level. Knowledge of this threshold level enables system designers to determine the circumvention scheme that will prevent data loss. The upset threshold level varies with each Advanced CMOS process, layout (design rules), and device-circuit design. This is generally one to two orders of magnitude lower than the latchup level.

Journal: :Blood purification 2014
Aarne J Vartia

BACKGROUND Patients dialyzed with equal eKt/V may have huge variations in their urea concentrations. METHODS Urea generation rate, distribution volume and renal clearance were determined in 205 hemodialysis sessions of 33 patients with double pool urea kinetic modeling using dialyzer clearance from online monitoring. From these data, optimized prescriptions were computed. RESULTS In simulat...