نتایج جستجو برای: ground heat exchanger
تعداد نتایج: 347966 فیلتر نتایج به سال:
this paper presents a simple methodology for cost estimation of a near optimal heat exchanger network, which comprises mixed materials of construction. intraditional pinch technology and mathematical programming it is usually assumed that all heat exchangers in a network obey a single cost model. this implies that all heat exchangers in a network are of the same type and use the same materials...
joule-thomson cooling systems are used in refrigeration processes such as cryogenic gas liquefaction. although extensive studies have been carried out by researchers, most of them include cryogenic heat exchangers and their associated fields. in the current study, an attempt was made to indicate the effect of using inappropriate operational conditions in a cryogenic joule-thomson cooling system...
In this study, the air-side pressure drop and heat transfer performance of plate-fin and microchannel coils were tested under clean and fouled conditions. The heat exchangers were tested with two different types of dust, ASHRAE dust and Arizona Road Test Dust. The ASHRAE dust was found to have a very significant impact on the pressure drop of the microchannel heat exchanger, increasing the air-...
In this study, the air-side pressure drop and heat transfer performance of plate-fin and microchannel coils were tested under clean and fouled conditions. The heat exchangers were tested with two different types of dust, ASHRAE Standard Dust and Arizona Road Test Dust. The ASHRAE dust was found to have a very significant impact on the pressure drop of the microchannel heat exchanger, increasing...
An experimental study has been conducted to evaluate the performance of a compact round-tube louver-fin condenser, each with frontal areas of 0.25 m in both dry and wet conditions. Deluge water cooling is achieved by incorporating a perforated bottom plate-type water distributor on top of the round tube heat exchanger. Water is used as a refrigerant, and enters the heat exchanger tubes at 35°C ...
In air-cooling applications with frost production, heat exchanger performance is often air-side limited, because the two-phase flow of the refrigerant provides excellent heat transfer coefficients, and because designers typically use a large air-side fin spacing for frost tolerance. The large fin spacing prolongs operation of the heat exchanger by mitigating the effect of the accumulating frost...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید