نتایج جستجو برای: interval impedance

تعداد نتایج: 234215  

 Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...

Journal: :فیزیک زمین و فضا 0
مصطفی عباسی دانشجوی کارشناسی ارشد ژئوفیزیک، گروه فیزیک زمین، مؤسسه ژئوفیزیک دانشگاه تهران، ایران محمدعلی ریاحی دانشیار، گروه فیزیک زمین، مؤسسه ژئوفیزیک دانشگاه تهران، ایران

in exploration seismology, estimation of elastic parameters of rocks using seismic amplitudes is considered as inverse problems. nowadays, model-based and more generally optimization-based algorithms are of the most common methods of seismic inversion. these algorithms which are known as deterministic methods, are suffering from two main problems; first, vertical resolution of outputs is very l...

Journal: :Journal of Alloys and Compounds 2021

The ceramics based on (Cu0·5Ag0.5)7SiS5I solid solution of superionic conductor with argyrodite structure were prepared by using the powders different particles size. structural studies performed XRD technique, while ceramic samples average size crystallites investigated microstructural analysis. total electrical conductivity was measured impedance spectroscopy in frequency range from 10 Hz to ...

Journal: :IEEE Trans. Systems, Man, and Cybernetics, Part A 1999
Toshio Tsuji Achmad Jazidie Makoto Kaneko

This paper proposes an impedance control method for redundant manipulators, which can control not only the endpoint impedance using one of the conventional impedance control methods, but the joint impedance which has no effects on the end-point impedance. First, a sufficient condition for the joint impedance controller is derived. Then, the optimal controller for a given desired joint impedance...

2010
Qinghai Shi Andreas Heinig Olfa Kanoun

Electrical impedance of biological matter is known as electrical bioimpedance or simply as bio-impedance. Bio-impedance devices are of great value for monitoring the pathological and physiological status of biological tissues in clinical and home environments. The technological progress in instrumentation has significantly contributed to the progress that has been observed during the last past ...

2012
Dario Ummarino Silvia Salvatore Bruno Hauser Annamaria Staiano Yvan Vandenplas

BACKGROUND The impedance baseline has been shown to reflect esophageal integrity, and to be decreased in patients with esophagitis. However, different methods for the determination of the impedance baseline have not been compared. METHODS The median impedance baseline was calculated in 10 consecutive multichannel intraluminal impedance recordings in children with non-erosive reflux disease. A...

Journal: :Journal of Instrumentation 2023

A line driver with configurable pre-emphasis is implemented in a 65 nm CMOS process. The utilizes three-tap feed-forward equalization (FFE) architecture. relative delays between the taps are selectable increments of 1/16th unit interval (UI) via an 8-stage delay-locked loop (DLL) and digital interpolator. It also possible to control output amplitude source impedance for each tap programmable ar...

Journal: :American journal of physiology. Gastrointestinal and liver physiology 2004
Hala Imam Claudia Sanmiguel Brett Larive Yasser Bhat Edy Soffer

Assessment of patterns of flow in the small bowel is difficult. Multiple intraluminal impedance has been recently used for study of flow dynamics in the esophagus. Our aims were 1) to validate multiple intraluminal impedance by correlating impedance events with intestinal flow as detected by fluoroscopy and 2) to determine intestinal flow patterns in the fasting and postprandial period and thei...

Journal: :Stereotactic and functional neurosurgery 2014
David Satzer David Lanctin Lynn E Eberly Aviva Abosch

BACKGROUND Deep brain stimulation (DBS) electrode impedance is a major determinant of current delivery to target tissues, but long-term variation in impedance has received little attention. OBJECTIVES To assess the relationship between electrode impedance and time in a large DBS patient population and characterize the relationship between contact activity and impedance. METHODS We collected...

Journal: :Plant physiology 1973
D R Evert

A sample holder was designed and built to facilitate measuring the magnitude and phase angle of the electrical impedance of internodal stem sections from Cornus stolonifera Michx. A nonpolarizing, electrically conducting manganese dioxidecarbon paste used between the stem sample and the electrodes of the sample holder allowed measurement of impedance at frequencies from 50 hertz to 500 kilohert...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید