نتایج جستجو برای: ion probe

تعداد نتایج: 294644  

2017
A. Wagner D. Seidman D. N. SEIDMAN

The effects of field-evaporation rate on the quantitative chemical analysis of materials by atom-probe field-ion microscopy are considered. Examples of erroneously high measured values of the Ti concentration in Mo-1.0 at.% Ti and Mo-1.0 at.% Ti-0.08 at.% Zr (TZM) alloys are presented and the cause is shown to have been due to a high field-evaporation rate. The basic arguments used to explain t...

Journal: :The Review of scientific instruments 2015
Tao Gong Zhichao Li Xiaohua Jiang Yongkun Ding Dong Yang Zhebin Wang Fang Wang Ping Li Guangyue Hu Bin Zhao Shenye Liu Shaoen Jiang Jian Zheng

A Thomson scattering diagnostic system, using a 263 nm laser as the probe beam, is designed and implemented on Shenguang-III prototype laser facility. The probe beam is provided by an additional beam line completed recently. The diagnostic system allows simultaneous measurements of both ion feature and red-shifted electron feature from plasmas in a high-temperature (≥2 keV) and high-density (≥1...

2004
Bernd Koch Jürgen Mlynek Gerd Fußmann

In fusion experiments, the energy flux to the target plates is an important issue. In order to spread the heat load, surfaces are usually designed to intersect magnetic field lines at very shallow angles. In the course of this work, a sensitive probe allowing simultaneous measurements of energy flux and current density as functions of a bias voltage was developed. Extensive experimental data on...

Journal: :Physical chemistry chemical physics : PCCP 2011
Damien Thompson Simon Coleman Dermot Diamond Robert Byrne

Liquid ion association in ionic liquids (ILs) has been examined using a comprehensive series of electronic structure calculations that measure the relative extents of ion association and probe stabilisation for the photochromic dye nitrobenzospiropyran (BSP) in a range of ILs featuring both long-tailed phosphonium cations and short-tailed imidazolium cations, paired with both chloride and NTf(2...

Journal: :The Review of scientific instruments 2016
S Costea B Fonda J Kovačič T Gyergyek B S Schneider R Schrittwieser C Ionita

Due to their ability to suppress a large part of the electron current and thus measuring directly the plasma potential, ion sensitive probes have begun to be widely tested and used in fusion devices. For these probes to work, almost perfect alignment with the total magnetic field is necessary. This condition cannot always be fulfilled due to the curvature of magnetic fields, complex magnetic st...

Journal: :Chemical communications 2012
Rui Wang Fabiao Yu Ping Liu Lingxin Chen

We have described a turn on fluorescent probe BOD-NHOH based on hydroxylamine oxidation for detecting intracellular ferric ions. The probe comprises a signal transducer of BODIPY dye and a Fe(3+)-response modulator of hydroxylamine. It is readily employed for assessing intracellular ferric ion levels, and confocal imaging is achieved successfully.

Journal: :Chemical communications 2015
Fanpeng Kong Xiaoyue Meng Ranran Chu Kehua Xu Bo Tang

Based on a unique elimination reaction prompted by the iodide ion, a novel turn-on fluorescence probe (HCy-OMe-Br) has been developed for the first time. The probe emits in the near infrared region with a large Stokes shift, and can respond rapidly to iodide with high selectivity and sensitivity.

Journal: :The Review of scientific instruments 2010
R Ochoukov D G Whyte B Lipschultz B Labombard S Wukitch

An ion sensitive probe (ISP) is developed as a robust diagnostic for measuring plasma potentials (Φ(P)) in magnetized plasmas. The ISP relies on the large difference between the ion and electron gyroradii (ρ(i)/ρ(e)∼60) to reduce the electron collection at a collector recessed behind a separately biased wall distance ∼ρ(i). We develop a new ISP method to measure the plasma potential that is ind...

Journal: :Micron 2008
Fabián Pérez-Willard Daniel Wolde-Giorgis Talaát Al-Kassab Gabriel A López Eric J Mittemeijer Reiner Kirchheim Dagmar Gerthsen

Needle-shaped atom probe specimens containing a single grain boundary were produced using the focused ion beam (FIB) of a two-beam FIB/SEM (scanning electron microscope) system. The presented specimen preparation approach allows the unprecedented study of a grain boundary which is well characterised in its crystallographic orientation by means of the field ion microscope (FIM) and the tomograph...

Journal: :The Review of scientific instruments 2012
J Klenzing D Rowland

A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication/Navigation Outage Forecast System (C/NOFS) satellite. C/NOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H(+) and O(+). The ion current collected by the probe surface per unit plasma density is found to b...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید