نتایج جستجو برای: iop

تعداد نتایج: 7489  

2013
Anne Herr Andreas Remky Thalia Hirsch Corinna Rennings Niklas Plange

INTRODUCTION Intraocular pressure (IOP) determination using dynamic contour tonometry (DCT) has been considered to be independent of central corneal thickness (CCT), while Goldmann applanation tonometry (GAT) is known to be influenced by various corneal properties. In this study, IOP was measured before and 1 day after cataract surgery using GAT and DCT to investigate the possible effects of co...

2012
Robin Bruen Mark R. Lesk Paul Harasymowycz

Purpose. To study the response to Selective Laser Trabeculoplasty (SLT) according to baseline medical treatment, angle pigmentation, age, diagnosis (open-angle glaucoma or ocular hypertension), and baseline intraocular pressure (IOP). Methods. 74 eyes of 74 patients were enrolled in this study. Baseline characteristics were recorded for each patient. IOP in the treated and fellow eyes was measu...

2014
Eleftherios I Paschalis Fabiano Cade Samir Melki Louis R Pasquale Claes H Dohlman Joseph B Ciolino

PURPOSE To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. METHODS The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion se...

Journal: :Journal of preventive medicine and public health = Yebang Uihakhoe chi 2010
Sang-shin Park Eun-Hee Lee Ganchimeg Jargal Domyung Paek Sung-il Cho

OBJECTIVES The current study was performed to assess the distribution of intraocular pressure (IOP) and its association with metabolic syndrome (MS) in a community. METHODS We measured IOP and MS components from 446 adults, age 20 or more years old, who reside in a community in Kyunggi Province, South Korea. We compared the level of IOP according to the number of metabolic abnormalities and b...

2018
Jessie Huang Paula Katalinic Michael Kalloniatis Michael P. Hennessy Barbara Zangerl

SIGNIFICANCE This article shows that self-tonometry can provide robust measures of diurnal intraocular pressure (IOP) and also detect changes to IOP in response to treatment within a short period of monitoring. These advances in IOP monitoring may contribute to improved management of glaucoma patients and suspects. PURPOSE The aim of this study was to prospectively investigate the utility of ...

2017
Yuan Fang Qingqing Long Xiaoqian Wang Rui Jiang Xinghuai Sun

Objective The aim of this study was to investigate the incidence, risk factors, and treatment of elevated intraocular pressure (IOP) 1 year after vitrectomy in eyes without a history of glaucoma or ocular hypertension. Patients and methods This retrospective study comprised 256 eyes from 256 consecutive patients without a history of glaucoma or ocular hypertension who underwent vitrectomy and...

2017
Daniel C. Turner Brian C. Samuels Carrie Huisingh Christopher A. Girkin J. Crawford Downs

Purpose To study the effect and time course of body position changes on IOP in nonhuman primates. Methods We recorded continuous bilateral IOP measurements with a wireless telemetry implant in three rhesus macaques in seven different body positions. IOP measurements were acquired in the seated-upright, standing, prone, supine, right and left lateral decubitus positions (LDPs), and head-down i...

Journal: :journal of research in medical sciences 0
razieh khajeh-kazemi msc student of biostatistics, department of epidemiology and biostatistics, tehran university of medical sciences, tehran, iran. banafsheh golestan department of epidemiology and biostatistics, tehran university of medical sciences, tehran, iran. kazem mohammad department of epidemiology and biostatistics, tehran university of medical sciences, tehran, iran. mahmoud mahmoudi department of epidemiology and biostatistics, tehran university of medical sciences, tehran, iran. saharnaz nedjat department of epidemiology and biostatistics, tehran university of medical sciences, tehran, iran. mohammad pakravan ophthalmic research center, shaheed beheshti university of medical sciences, tehran, iran.

background: the celebrated generalized estimating equations (gee) approach is often used in longitudinal data analysis. while this method behaves robustly against misspecification of the working correlation structure, it has some limitations on efficacy of estimators, goodness-of-fit tests and model selection criteria. the quadratic inference functions (qif) is a new statistical methodology tha...

2016
Yeji Moon Junki Kwon Da Woon Jeong Jin Young Lee Jong Rak Lee Seungbong Han Michael S. Kook

OBJECTIVE To characterize the 24-h habitual-position intraocular pressure (IOP) patterns of optic disc phenotypes (ODPs) in untreated normal-tension glaucoma (NTG) and the relationships between nocturnal IOP elevation and various clinical factors. DESIGN Prospective, cross-sectional, observational study. METHODS Eighty-two NTG patients with focal ischemic (FI) ODP and 82 age- and disease se...

2017
Pei Xu Ting Xia Jianbin Chen

Objective: The evaluation of intraocular pressure (IOP) after vitreoretinal surgery is critical to ensure the normal function of the eye. The purpose of this study was to determine the incidences and risk factors of early postoperative IOP elevation after vitreoretinal surgery. Method: Data were collected and retrospectively analyzed from 150 patients (150 eyes) who received vitreoretinal surge...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید