نتایج جستجو برای: legionella

تعداد نتایج: 4966  

Journal: :Euro surveillance : bulletin Europeen sur les maladies transmissibles = European communicable disease bulletin 2011
M Arvand K Jungkind A Hack

German water guidelines do not recommend routine assessment of cold water for Legionella in healthcare facilities, except if the water temperature at distal sites exceeds 25°C. This study evaluates Legionella contamination in cold and warm water supplies of healthcare facilities in Hesse, Germany, and analyses the relationship between cold water temperature and Legionella contamination. Samples...

Journal: :Clinical infectious diseases : an official publication of the Infectious Diseases Society of America 1998
Z Liu J E Stout M Boldin J Rugh W F Diven V L Yu

One copper-silver ionization system was sequentially installed onto the hot-water recirculation lines of two hospital buildings colonized with Legionella pneumophila, serogroup 1. A third building with the same water supply and also colonized with Legionella served as a control. Four weeks after activation of the system, distal site positivity for Legionella in the first test building dropped t...

Journal: :The Journal of antimicrobial chemotherapy 1997
C Bébéar D H Bouanchaud

Quinupristin/dalfopristin displays in-vitro bacteriostatic activity against all Legionella spp. (MICs = 0.06-2 mg/L), with Legionella pneumophila usually being at least two-fold more sensitive to quinupristin/dalfopristin than Legionella bozemanii, Legionella dumoffii, Legionella gormanii and Legionella micdadei (MIC = 0.06-2 vs 1-2 mg/L, respectively). Against Legionella spp., quinupristin/dal...

Journal: :Journal of immunology 2008
Maya Vinzing Julia Eitel Juliane Lippmann Andreas C Hocke Janine Zahlten Hortense Slevogt Philippe Dje N'guessan Stefan Günther Bernd Schmeck Stefan Hippenstiel Antje Flieger Norbert Suttorp Bastian Opitz

In mice, different alleles of the mNAIP5 (murine neuronal apoptosis inhibitory protein-5)/mBirc1e gene determine whether macrophages restrict or support intracellular replication of Legionella pneumophila, and whether a mouse is resistant or (moderately) susceptible to Legionella infection. In the resistant mice strains, the nucleotide-binding oligomerization domain (Nod)-like receptor (NLR) fa...

Journal: :Journal of clinical microbiology 1981
L G Cordes R L Myerowitz A W Pasculle L Corcoran T A Thompson G W Gorman C M Patton

Legionella micdadei (Pittsburgh pneumonia agent) was identified by direct fluorescent-antibody (DFA) examination of lung tissue in six of seven persons diagnosed previously as having L. micdadei pneumonia only by histopathology and in four persons who also had positive cultures of the organism. No cross-reactions occurred with monospecific DFA conjugates prepared against Legionella pneumophila ...

Journal: :Applied and environmental microbiology 1984
S C Hsu R Martin B B Wentworth

Three different species of Legionella were recovered from samples of water taken from chlorinated public water supplies where no coliform bacteria were simultaneously detected. Five of 856 samples yielded Legionella isolates. Three isolates were identified as Legionella pneumophila serogroup 1, the fourth was identified as Legionella dumoffii, and the fifth was identified as Legionella jordanis...

Journal: :Advanced pharmaceutical bulletin 2013
Reza Ghotaslou Fatemeh Yeganeh Sefidan Mohammad Taghi Akhi Mohammad Hussein Soroush Mohammad Saeid Hejazi

PURPOSE The present study was designed to evaluate the occurrence of Legionella contamination in the tap water of Tabriz hospitals, Azerbaijan, Iran. METHODS One hundred and forty water samples from diverse water supply systems of 17 hospitals were collected and analyzed for the presence of Legionella spp. by PCR assay. RESULTS In this study, 10 of 140 (7.1%) samples were positive for Legio...

Journal: :Journal of clinical microbiology 1983
W L Thacker H W Wilkinson R F Benson

It is technically impractical for many clinical laboratories to use the direct immunofluorescence assay for identifying and serogrouping clinical isolates of Legionella. We compared the results obtained with the direct immunofluorescence assay with the results of a simple and less-demanding slide agglutination test for identifying 15 serogroups representing seven Legionella species. The slide a...

2014
T Reynaldos Canton Migotto S Györik Lora V Gaia A Pagnamenta

  Legionella longbeachae is a very uncommon cause of community acquired pneumonia in Western countries. L. longbeachae does not grow on blood agar media and is usually not detected by sputum gram stain or blood culture. Furthermore Legionella urinary antigen testing fails to detect it. In this report we described a 79-year-old man with polymyalgia rheumatica under systemic corticosteroid treatm...

Journal: :The Southeast Asian journal of tropical medicine and public health 2006
Chomrach Sirigul Waranya Wongwit Wantanee Phanprasit Wantana Paveenkittiporn Stuart D Blacksell Pongrama Ramasoota

The objective of this study was to develop and optimize the combined methods of air sampling and real time polymerase chain reaction (real-time PCR) for quantifying aerosol Legionella spp. Primers and TaqMan hydrolysis probe based on 5S rRNA gene specific for Legionella spp were used to amplify a specific DNA product of 84 bp. The impinger air sampler plus T-100 sampling pump was used to collec...

نمودار تعداد نتایج جستجو در هر سال