نتایج جستجو برای: linear array imaging

تعداد نتایج: 1037855  

Journal: :Circulation 1976
O T vonRamm F L Thurstone

A new two-dimensional, real-time, high resolution ultrasound imaging system is described. This system uses a linear array of ultrasound transducers to generate tomographic images of the heart in a circular sector format. Phased array techniques allow rapid steering of the ultrasound beam so that images are produced at the rate of 20 per second, or more, while maintaining a resolution of 2-4 mm ...

Journal: :Optics express 2009
John Gamelin Anastasios Maurudis Andres Aguirre Fei Huang Puyun Guo Lihong V Wang Quing Zhu

A real-time 512-element photoacoustic tomography system for small animal imaging using a ring ultrasound array has been developed. The system, based upon a 5 MHz transducer array formed along a 50 mm circular aperture, achieves sub-200 micron lateral resolution over a 2 cm disk-shaped region. Corresponding elevation resolutions of 0.6 to 2.5 mm over the central volume enable depth-resolved 3D t...

2001
John A. Hossack Jun S. Ha Thilaka S. Sumanaweera

An approach for acquiring dimensionally accurate 3D ultrasound data, based on a modified 1D transducer array, is presented. The method avoids many of the drawbacks of conventional approaches to 3D ultrasound data acquisition. Scanning is simple and easy to perform in a clinical setting. A modified 1D transducer array is employed comprising a central conventional 1D ‘Imaging’ array and two perpe...

2008
Kirk Shung

ihong V. Wang ashington University in St. Louis ptical Imaging Laboratory epartment of Biomedical Engineering t. Louis, Missouri 63130 -mail: [email protected] Abstract. We present an in vivo dark-field reflection-mode photoacoustic microscopy system that performs cross-sectional B-scan imaging at 50 Hz with real-time beamforming and 3-D imaging consisting of 166 B-scan frames at 1 Hz wit...

Bekrani, M. ,

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

Bekrani, M. ,

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

Journal: :Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan 1994

Journal: :international journal of electrical and electronics engineering 0
reza gholami shariatee st. p.o. box 47135-484, babol, iran bijan zakeri shariati st babol hossein mehrpour bernety

this paper presents a low-cost compact planar microstrip-fed monopole antenna and its four-element array design for ultra-wideband (uwb) wireless communication and target detection applications, respectively, operating in the frequency span of 3 ghz to 11 ghz. a prototype was fabricated and then measured based on optimal parameters. the results of reflection coefficient (s11) and radiation patt...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید