نتایج جستجو برای: noble gas sensor

تعداد نتایج: 434166  

2001
W. OLTHUIS

Acid or base concentrations can be determined by coulometric titration. A new alliridium oxide sensor-actuator device is presented, of which the titrant is generated by a reversible redox reaction occurring in the electroactive iridium oxide actuator electrode, and the equivalence point in the titration curve is detected by the pH-sensitive iridium oxide sensor. The advantage with respect to th...

2016
Cheng Zhu Markku Räsänen

..................................................................................................................................... 3 Acknowledgements .................................................................................................................... 4 List of publications ...........................................................................................................

Journal: :Angewandte Chemie 2001
Karl O. Christe

Form Approved 0MB No. 0704-0188 Public r-pcning burden ior this collection of iniormation is estimated to average 1 hour per response, inci jding the time for reviewing instruciions, searching existing data sources, gathering and mainiaininc the data needed, and completing and reviewing this collection of information. Send commer.ls regarding this burden estimate or any other aspect of this col...

2004
M. Mazzanti Y.-S. Tseng J. Chen J. Mansour N. Shah Y. Sun

Introduction Hyperpolarized noble gas magnetic resonance imaging (HP gas MRI) is a new and innovative imaging method that has made it possible, for the first time, to obtain high resolution MR images of air-filled organs such as the lungs, as well as lipid rich tissue such as the brain. Unlike conventional MRI which relies on the detection of water protons in biological tissue, HP gas MRI is ba...

Journal: :Journal of Applied Physics 2006

Journal: :Chemical Physics Letters 2014

In this paper, design and simulation of a new highly sensitive gas sensor based on a hybrid photonic crystal (PC) structure, containing negative and positive refractive index sections, is presented. It has been shown that using a PC with negative refraction in the first section, the transmitted power is concentrated on the entrance of the sensing channel, and the transmission of the proposed se...

2009
Lin Ma Maria Clara Castro Chris M. Hall

[1] Noble gas concentrations and isotopic ratios are presented for 38 deep ( 0.5–3.6 km) brine samples in the Michigan Basin. These brine samples clearly show the presence of an important crustal component of He, Ne, Ar, and Xe. Both Arcrust and Xecrust display the presence of a strong vertical gradient along the sedimentary strata of the basin. We show that the in situ production for these two...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید