نتایج جستجو برای: optical reflectance

تعداد نتایج: 282209  

2013
Z. Ghassemlooy D. Wu M. A. Khalighi X. Tang

Indoor Non-directed Optical Wireless Communications Optimization of the Lambertian Order Z. Ghassemlooy1,*, D. Wu1, M. A. Khalighi2, and X. Tang3 1Optical Communications Research Group, Faculty of Engineering and Environment, Northumbria University, Newcastle Upon Tyne, UK 2Ecole Centrale Marseille, Institute Fresnel, Marseille, France 3 Department of Electronic Engineering, Tsinghua University...

Journal: :Journal of biomedical optics 2007
Malavika Chandra James Scheiman David Heidt Diane Simeone Barbara McKenna Mary-Ann Mycek

Pancreatic adenocarcinoma, one of the leading causes of cancer death in the United States, has a five-year survival rate of only 4%. Present detection methods do not provide accurate diagnosis in the disease's early stages. To investigate whether optical spectroscopy could potentially aid in early diagnosis and improve survival rates, reflectance and fluorescence spectroscopies were employed fo...

Journal: :Applied optics 2010
Nicole Brimhall Nicholas Herrick David D Allred R Steven Turley Michael Ware Justin Peatross

We use a laser high-harmonics-based extreme-ultraviolet (EUV) polarimeter to determine the optical constants of elemental uranium in the wavelength range from 10 to 47 nm. The constants are extracted from the measured ratio of p-polarized to s-polarized reflectance from a thin uranium film deposited in situ. The film thickness is inferred from a spectroscopic ellipsometry measurement of the sam...

Journal: :Biomedical optics express 2014
Sheldon F Bish Manu Sharma Youmin Wang Nicholas J Triesault Jason S Reichenberg John X J Zhang James W Tunnell

Diffuse reflectance spectroscopy provides a noninvasive means to measure optical and physiological properties of tissues. To expand on these measurements, we have developed a handheld diffuse reflectance spectral imaging (DRSi) system capable of acquiring wide field hyperspectral images of tissue. The image acquisition time was approximately 50 seconds for a 50x50 pixel image. A transport model...

We report on transparent ZnO/Ag/ZnO and ZnO/Ag/ZnO/Ag/ZnO thin-films were deposited on the glass substrate by RF and DC sputtering for ZnO and Ag targets, respectively. The electrical and optical properties of the single and double Low Emissivity coatings were investigated with respect to the deposition time of Ag mid layer. The visible transmittance remains about 65% for single and 45% for...

Journal: :Optics express 2001
C Liang M Descour K B Sung R Richards-Kortum

In-vivo imaging can be achieved with a coherent-fiber-bundle based confocal reflectance microscope. Such a microscope could provide the means to detect pre-cancerous lesions in the cervix by characterizing cells' nuclear-to-cytoplasmic ratio. In this paper we present the design of such a fiber confocal reflectance microscope, with an emphasis on its optical sub-systems. The optical sub-systems ...

2017
Francesco Floris Lucia Fornasari Andrea Marini Vittorio Bellani Francesco Banfi Stefano Roddaro Daniele Ercolani Mirko Rocci Fabio Beltram Marco Cecchini Lucia Sorba Francesco Rossella

Subwavelength nanostructured surfaces are realized with self-assembled vertically-aligned InAs nanowires, and their functionalities as optical reflectors are investigated. In our system, polarization-resolved specular reflectance displays strong modulations as a function of incident photon energy and angle. An effective-medium model allows one to rationalize the experimental findings in the lon...

2010
Hyeongwoo Kim Bennett Wilburn Moshe Ben-Ezra

We present a photometric stereo method for non-rigid objects of unknown and spatially varying materials. The prior art uses timemultiplexed illumination but assumes constant surface normals across several frames, fundamentally limiting the accuracy of the estimated normals. We explicitly account for time-varying surface orientations, and show that for unknown Lambertian materials, five images a...

Journal: :Applied optics 2006
Antti Lamminpää Saulius Nevas Farshid Manoocheri Erkki Ikonen

The optical parameters of a SiO2 thin-film coating determined from the spectral reflectance and transmittance measurements at various incidence angles, including the normal incidence and the Brewster's angle, are compared in this paper. The high-accuracy measurements were carried out through visible-near-infrared spectral regions by using our purpose-built instruments. The optical parameters ob...

Journal: :Optics letters 2001
A Kienle F K Forster R Hibst

Spatially resolved reflectance measurements are widely used for determination of the optical properties of biological media. However, the influence of the phase function on these measurements has not been quantified. We show that errors in the derived reduced scattering and absorption coefficients are as great as 100% for both absolute and relative spatially resolved reflectance measurements if...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید