نتایج جستجو برای: peek cage
تعداد نتایج: 15587 فیلتر نتایج به سال:
Despite its widespread clinical use in load-bearing orthopedic implants, polyether-ether-ketone (PEEK) is often associated with poor osseointegration. In this study, a surface-porous PEEK material (PEEK-SP) was created using a melt extrusion technique. The porous layer was 399.6±63.3 μm thick and possessed a mean pore size of 279.9±31.6 μm, strut spacing of 186.8±55.5 μm, porosity of 67.3±3.1% ...
Objective: With the latest advances and innovations in field of spine surgery, new generation surgeons has been increasingly preferring endoscopic lumbar interbody fusion technique to treat pathology degenerative disease. The aim this study was elucidate clinical radiologic outcomes biportal with a long polyetheretherketone (PEEK) cage.Methods: This included 40 patients treated by PEEK cage bet...
The effects of surface modifications of multi-walled carbon nanotubes (MWCNTs) on their dispersibility in different solvents and poly (ether ether ketone) (PEEK) have been studied. MWCNTs were treated by mixed acids to obtain acid-functionalized MWCNTs. The acid-functionalized MWCNTs were modified with six different chemical agents separately, 1,6-diaminohexane, hexadecyl trimethyl ammonium bro...
BACKGROUND Compared with titanium (Ti) and other metal implant materials, poly(ether-ether ketone) (PEEK) shows outstanding biomechanical properties. A number of studies have also reported attractive bioactivity for nano-TiO(2) (n-TiO(2)). METHODS In this study, n-TiO(2)/PEEK nanocomposites were prepared, taking advantage of the unique properties of both PEEK polymer and n-TiO(2). The in vitr...
Despite the excellent osseointegration of carbon-fiber-reinforced polyetheretherketone (CFR/PEEK) with a surface hydroxyapatite (HA) coating, the bone-implant interfacial shear strength of HA-coated CFR/PEEK after osseointegration is unclear. We examined the interfacial shear strength of HA-coated CFR/PEEK implants after in vivo implantation in a rabbit femur-implant pull-out test model. HA coa...
Fractured abutment screws may be replaced; however, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced. The aim of this study was to compare the fracture resistance of abutment retention screws made of titanium, polyetheretherketone (PEEK) and 30% carbon fiber-reinforced PEEK, using an external hexagonal implant/UCLA-type abutment interface ass...
BACKGROUND Polyetheretherketone (PEEK) and its composites are polymers resistant to fatigue strain, radiologically transparent, and have mechanical properties suitable for a range of orthopaedic applications. In bulk form, PEEK composites are generally accepted as biocompatible. In particulate form, however, the biologic response relevant to joint replacement devices remains unclear. The biolog...
A 65-year-old male originally had surgery for spondylolisthesis at L5-S1 in 2008 and then went on to have an L4-5 transforaminal lumbar interbody fusion (TLIF) with pedicle screw fixation from L4 to S1 and interbody graft in 2010. Despite having two surgical procedures, he continued with intractable back pain and was told he had a failed lumbar fusion. When he was evaluated with a computerized ...
Polyetheretherketone (PEEK), which has biomechanical performance similar to that of human cancellous bone, is used widely as a spinal implant material. However, its bioinertness and hydrophobic surface properties result in poor osseointegration. This study applies a novel modification method, arc ion plating (AIP), that produces a highly osteoblast compatible titanium dioxide (TiO2) coatings on...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید