نتایج جستجو برای: potentiometry ion selective membrane electrode

تعداد نتایج: 802881  

Journal: :Drug Analytical Research 2021

A method based on microwave-induced combustion (MIC) was applied for medicinal plants digestion allowing further chlorine determination by potentiometry using ion-selective electrode (ISE). Sample masses ranging from 500 to 1000 mg were evaluated MIC digestion. Water and 10, 25, 50, 100 mmol/L NH4OH investigated as absorbing solutions. The accuracy of the proposed certified reference materials ...

A. Islamnezhad E. D. Zobairi Sh. Keyvan,

A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...

Journal: :The Analyst 2014
K Melzer A M Münzer E Jaworska K Maksymiuk A Michalska G Scarpa

In this work the ion-selective response of an electrolyte-gated carbon-nanotube field-effect transistor (CNT-FET) towards K(+), Ca(2+) and Cl(-) in the biologically relevant concentration range from 10(-1) M to 10(-6) M is demonstrated. The ion-selective response is achieved by modifying the gate-electrode of an electrolyte-gated CNT-FET with ion-selective membranes, which are selective towards...

Journal: :Langmuir : the ACS journal of surfaces and colloids 2015
Charles G Cranfield Taren Bettler Bruce Cornell

The nanoscale spacing between a tethered lipid bilayer membrane (tBLM) and its supporting gold electrode can be utilized to determine the polarity selectivity of the conduction of ion channels and ion carriers embedded in a membrane. The technique relies upon a bias voltage sequestering or eliminating ions, of a particular polarity, into or out of the aqueous electrolyte region between the gold...

A. Islamnezhad E. D. Zobairi Sh. Keyvan,

A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...

2017

Submit Manuscript | http://medcraveonline.com immense number of publications appeared dealing mainly with the determination of the four “classical” metals easily accessible by inverse voltammetry on mercury electrodes, i.e., Zn, Cd, Pb and Cu. Along with such prosperity in voltammetry also potentiometry slipped into its golden age with the development of new ion selective membranes for many of ...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2007
Yoshihiro Kudo Ryo Fujihara Shoichi Katsuta Yasuyuki Takeda

The ion-pair formation constant (K(MLA)(0) in mol(-1) dm(3)) for Li(B15C5)(+) with a picrate ion (Pic(-)) in water was determined by potentiometry with a K(+)-selective electrode at 25 degrees C and an ionic strength of 0, where B15C5 denotes benzo-15-crown-5 ether. Using the concentration equilibrium constants, K(MLA), estimated from this value, the extraction constants (mol(-2) dm(6) unit) of...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید