نتایج جستجو برای: screw

تعداد نتایج: 16204  

2015
Mohammad Kamran Shahid

Shahid Technique’ to help reduce suitable fracture configurations to facilitate ease of the Lag Screw Principle. In oblique fracture configurations, inter fragmentary compression at a fracture site can be achieved using the ‘Lag Screw Principle’. A screw inclination perpendicular to the fracture plane in this configuration allows for optimal compression. If compression is applied at an angle gr...

Journal: :Acta orthopaedica Belgica 2005
Vinay Parmar Shyam Kumar Aster Aster William H Harper

This review considers methods used to quantify lag screw placement within the femoral head following proximal femoral fracture. Implants used for fixation of femoral neck fractures can lead to unwanted outcomes in some patients. Cutting out of the screw within the femoral head has been shown to be the commonest cause of failure and is related to lag screw placement within the femur. Until now, ...

Journal: :Injury 2014
Tim Schepers Hans van der Linden Esther M M van Lieshout Dieu-Donné Niesten Maarten van der Elst

INTRODUCTION Much of the currently available data on the technical aspects of syndesmotic screw placement are based upon biomechanical studies, using cadaveric legs with different testing protocols, and on surgeon preference. The primary aim of this study was to investigate the effect of the level of syndesmotic screw insertion on functional outcome. Further, the effects of number of cortices e...

2017
Brian Fiani Syed A Quadri Vivek Ramakrishnan Blake Berman Yasir Khan Javed Siddiqi

Introduction Pedicle screw insertion is the mainstay of thora-cic and lumbosacral posterior spinal instrumentation. However, it may be associated with complications such as screw mal-positioning. The purpose of this study was to develop a pilot study to compare the accuracy of robot-guided screw insertion versus hand-guided screw placement for spinal instrumentation. The hand-guided screws were...

2016
Ai-Min Wu Yong-Long Chi Wen-Fei Ni Yi-Xing Huang Ferdinand Frauscher

BACKGROUND Surgical treatments for adult spinal deformities often include pelvic fixation, and the feasibility of sacral-2 alar iliac (S2AI) screw fixation has been shown previously. However, sometimes S2AI screw fixation cannot be applied due to the presence of an osteolytic lesion or trauma or because the biomechanical properties of only an S2AI screw is insufficient. Therefore, we questioned...

Journal: :Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons 2007
Gerrit J Buijs Eduard B van der Houwen Boudewijn Stegenga Rudulf R M Bos Gijsbertus J Verkerke

PURPOSE To determine 1) the differences in maximum torque between 7 biodegradable and 2 titanium screw systems, and 2) the differences of maximum torque between "hand tight" and break of the biodegradable and the titanium osteofixation screw systems. MATERIALS AND METHODS Four oral and maxillofacial surgeons inserted 8 specimens of all 9 screw systems in polymethylmethacrylate plates. The sur...

2018
D. Franks J. Shatrov M. Symes D. G. Little T. L. Cheng

Purpose Lateral condyle fractures of the humerus are common in the paediatric population, accounting for up to 20% of elbow fractures. Traditional management involves internal fixation with Kirschner (K)-wires, however, this has been associated with complications and insufficiently rigid fixation. Recently, cannulated screws have been proposed as a more stable method of fixation. While cannulat...

2014
Hae-Gi Park Moo-Sung Kang Kyung-Hyun Kim Jeong-Yoon Park Keun-Su Kim Sung-Uk Kuh

OBJECTIVE We describe a surgical tool that uses the distractor pin as a reference for determining proper screw length in ACDF. It is critical that screw purchase depth be as deep as possible without violating or penetrating the posterior cortical wall, which ensures strong pull out strength. METHODS We enrolled 81 adult patients who underwent ACDF using an anterior cervical plate from 2010 to...

2016
Nihat Acar Ahmet Karakasli Ahmet A. Karaarslan Mehmet Hilal Ozcanhan Fatih Ertem Mehmet Erduran

OBJECTIVE Rod-screw fixation systems are widely used for spinal instrumentation. Although many biomechanical studies on rod-screw systems have been carried out, but the effects of rod contouring on the construct strength is still not very well defined in the literature. This work examines the mechanical impact of straight, 20° kyphotic, and 20° lordotic rod contouring on rod-screw fixation syst...

Journal: :Spine 2010
Hossein Elgafy Tejaswy Potluri Vijay K Goel Scott Foster Ahmad Faizan Nikhil Kulkarni

STUDY DESIGN This is an in vitro biomechanical study. OBJECTIVE To compare the biomechanical stability of the 3 C1-C2 transarticular screw salvaging fixation techniques. SUMMARY AND BACKGROUND DATA Stabilization of the atlantoaxial complex is a challenging procedure because of its complicated anatomy. Many posterior stabilization techniques of the atlantoaxial complex have been developed wi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید