ALEKSANDAR RADU TANJA RADU CHRISTINA McGRAW PETER DILLINGHAM SALZITSA ANASTASOVA - IVANOVA DERMOT DIAMOND

An overview is given dealing with the application of ion-selective electrodes (ISEs) in environmental analysis. ISEs are placed into the context of the trend of development of sensors for extensive and frequent monitoring. Discussed are the issues such as sensing platforms and their mass-production, improvement of precision, diagnostic of sensor functionality, and development of reference elect...

Journal: :Clinical chemistry 1978
E A Mangubat T R Hinds F F Vincenzi

A method based on standard additions to the sample was used to measure potassium (K+) in human erythocytes with an ion-selective electrode. A computer program was developed for rapid analysis of data obtained with the electrode. The analysis takes into account factors such as temperature that may affect electrode behavior. Results obtained by the method agree with those obtained by flame-emissi...

2012
Mohsen M. Zareh

In the last four decades, the uses and application of ion-selective electrodes was widely applied in several researches as well as analytical projects. These electrodes are varied between solid state electrodes, liquid membrane electrodes, gas membrane electrodes, and plastic membrane electrodes. Plasticizers are one of the major components of the plastic membranes. As it is usually known, they...

2004

A theory for the interpretation of the operation mechanism of ion-selective membrane electrodes is briefly outlined. The statements are based on the accumulated results concerning the electrochemical and spectrochemical behaviour of ion-selective membranes.

Journal: :Clinical chemistry 1985
J Toffaletti K M Lee

We analyzed 93 sera and 81 whole-blood samples, plus several aqueous materials and one serum-based material as controls, with two analyzers for ionized calcium (Radiometer ICA 1 and AVL 980). On 16 days, comparisons of results for patients' samples were good, with nearly all between-instrument differences (delta Ca2+) of samples being within 0.04 mmol/L. On 12 days, comparisons were mediocre, w...

Journal: :The Journal of Automatic Chemistry 1991
Rui A. S. Lapa José L. F. C. Lima

The construction of a microcomputer-controlled electrode switch for use in potentiometric determinations is described. This can be coupled to most of the analytical equipment usually found in laboratories, to enable a setting up of automatic systems capable of performing sequential determinations with several ion-selective electrodes. The assessment of its analytical usage and behaviour are dis...

2013

Where E0 is the standard electrode potential, R is the universal gas constant, T is the absolute temperature, z is the number of moles of electrons transferred in the cell reaction or halfreaction, F is the Faraday-constant, and cox and cred are the concentrations of the oxidized and reduced forms of the component. The potential of the hydrogen electrode is declared to be 0.000 V at all tempera...

H. Aghaie K. Zare M. Aghaie M. Arvand M. Kia

A new poly(vinylchloride) membrane sensor for Cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. The electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with aNernstian slope of 20.3 ± 0.5 mV per decade and a detection limit of 2×10-7. It has a fast responsetime of

A simple and selective carbon paste electrode has been developed for the electrochemicaldetermination of acyclovir (ACV). This electrode was designed by incorporation of multiwalledcarbon nanotubes (MWCNTs) and ZnO nanoparticles into the carbon paste matrix,and then poly (o-aminophenol; OAP) film were subsequently electropolymerized on it. Thesurface structure of nanoparticles were characterize...