نتایج جستجو برای: sulfur hexafluoride

تعداد نتایج: 32829  

Journal: :Applied human science : journal of physiological anthropology 1999
S Demura H Kobayashi K Tanaka S Sato Y Nagasawa T Murase

The present study investigated the validity, reliability, objectivity, and practicability of methods with skinfold caliper (SF), ultrasound (US), bioelectrical impedance (BI), and sulfur hexafluoride (SHD) using identical subjects, and evaluated comprehensive usefulness by comparing selected methods or equations. In examining validity, underwater weighing (UW) was employed to obtain the criteri...

Journal: :Analytical chemistry 2003
Michael May Todd Poeppelmeier John Kuo

A rugged jet expansion module was designed, built, and utilized to sample liquefied gas for gas chromatography-discharge ionization detector (GC-DID) analysis. The module is inserted at an intermediate stage between a higher pressure sample cylinder and lower pressure gas injection manifold. The title jet module permits selection of liquid-phase or vapor-phase sampling by setting the valve-cyli...

Journal: :Nanoscale 2015
A Malumbres G Martínez J L Hueso J Gracia R Mallada A Ibarra J Santamaría

Stable, alkyl-terminated, light-emitting silicon nanoparticles have been synthesized in a continuous process by laser pyrolysis of a liquid trialkyl-silane precursor selected as a safer alternative to gas silane (SiH4). Stabilization was achieved by in situ reaction using a liquid collection system instead of the usual solid state filtration. The alkene contained in the collection liquid (1-dod...

2015
Antoine Camper Amélie Ferré Nan Lin Emmanouil Skantzakis Frédéric Burgy Stéphane Petit Dominique Descamps Thierry Auguste Olivier Gobert Bertrand Carré Yann Mairesse Thierry Ruchon

We report on high-order harmonic (HHG) two-source interferometry (TSI) in molecular gases. We used a 0-π phase plate to create two bright spots at the focus of a lens by converting a Gaussian laser beam into a TEM01 Transverse Electromagnetic Mode. The two bright foci produce two synchronized HHG sources. One of them is used to probe on-going dynamics in the generating medium, while the other s...

Journal: :Physical review. E, Statistical, nonlinear, and soft matter physics 2006
Yves Garrabos Fabien Palencia Carole Lecoutre Can Erkey Bernard Le Neindre

We present the master (i.e., unique) behavior of the correlation length, as a function of the thermal field along the critical isochore, asymptotically close to the gas-liquid critical point of xenon, krypton, argon, helium-3, sulfur hexafluoride, carbon dioxide, and heavy water. It is remarkable that this unicity extends to the correction-to-scaling terms. The critical parameter set, which con...

Journal: :Proceedings of the National Academy of Sciences of the United States of America 2014
Luca Turin Efthimios M C Skoulakis Andrew P Horsfield

We show that the general anesthetics xenon, sulfur hexafluoride, nitrous oxide, and chloroform cause rapid increases of different magnitude and time course in the electron spin content of Drosophila. With the exception of CHCl3, these changes are reversible. Anesthetic-resistant mutant strains of Drosophila exhibit a different pattern of spin responses to anesthetic. In two such mutants, the sp...

Journal: :The Annals of occupational hygiene 2013
Rong Fung Huang Jia-Kun Chen Ji-Heng Lee

In order to increase containment efficiency and reduce energy consumption, an inclined quad-vortex range hood (IQV range hood) was developed and tested by experimental methods. The flow structure was observed by a laser-assisted flow visualization technique and laser Doppler velocimetry (LDV). Leakage characteristics were measured by the tracer gas (sulfur hexafluoride) detection method. By arr...

Journal: :Journal of environmental quality 2002
Kelly Addy D Q Kellogg Arthur J Gold Peter M Groffman Gina Ferendo Carl Sawyer

To quantify ground water denitrification in discrete locations of riparian aquifers, we modified and evaluated an in situ method based on conservative tracers and 15N-enriched nitrate. Ground water was "pushed" (i.e., injected) into a mini-piezometer and then "pulled" (i.e., extracted) from the same mini-piezometer after an incubation period. This push-pull method was applied in replicate mini-...

Journal: :Journal of applied physiology 1998
G K Prisk A R Elliott H J Guy S Verbanck M Paiva J B West

We performed multiple-breath washouts of N2 and simultaneous washins of He and SF6 with fixed tidal volume (approximately 1,250 ml) and preinspiratory lung volume (approximately the subject's functional residual capacity in the standing position) in four normal subjects (mean age 40 yr) standing and supine in normal gravity (1 G) and during exposure to sustained microgravity (microG). The prima...

Journal: :Environmental science & technology 2005
Rik Wanninkhof Kevin F Sullivan W Paul Dammann John R Proni Frederick Bloetscher Alexander V Soloviev Thomas P Carsey

Pathways and dilution of a point source ocean discharge in the farfield (approximately to 10-66 km) were measured using the deliberate tracer sulfur hexafluoride (SF6). The injection of SF6 was performed by bubbling the gas over a period of 6 days into an ocean outfall pipe discharging into the southeast Florida coastal ocean. The surface SF6 concentrations show that the discharged water flowed...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید