2008
Tina Marie Briere Ramesh Tailor Naresh Tolani Karl Prado Richard Lane Shiao Woo Chul Ha Michael T. Gillin A. Sam Beddar

We studied the usefulness of a new type of solid-state detector, the OneDose single-use MOSFET (metal oxide semiconductor field effect transistor) dosimeter, for entrance dose measurements for total body irradiation (TBI). The factory calibration factors supplied by the manufacturer are applicable to conventional radiotherapy beam arrangements and therefore may not be expected to be valid for T...

Journal: :International journal of radiation oncology, biology, physics 2012
J Lah D Kim S Park

PURPOSE To evaluate the suitability of the GD-301 glass dosimeter for use in in vivo dose verification in proton therapy. METHODS The glass dosimeter was analyzed for its dosimetric characteristic in proton beam. Dosimeters were calibrated in a water phantom using a stair-like holder specially designed for this study. To determine the accuracy of the glass dosimeter in proton dose measurement...

Journal: :Medical physics 2013
M Carroll G Ibbott M Gillin J Adamovics

PURPOSE This investigation studies the feasibility of PRESAGE, a 3D polyurethane dosimeter, for relative dosimetry measurements of clinically relevant proton treatments using an anthropomorphic head phantom developed by the Radiological Physics Center (RPC). Performance of a low-LET dependent PRESAGE was evaluated by comparison to the traditionally used radiochromic film, EBT2, and thermolumine...

2008
Patricia Mora Mariela Porras-Chaverri

The Thermoluminescence Personal Dosimetry Laboratory of the University of Costa Rica provides dose measurements for around 90% of occupational radiation workers in the country. The assessment of doses to workers routinely exposed to external sources of radiation constitutes an integral part of any radiation protection programme and helps national authorities to ensure acceptably safe and satisf...

2012
Stephen F. Kry Susan A. Smith Rita Weathers Marilyn Stovall

The skin dose associated with radiotherapy may be of interest for clinical evaluation or investigating the risk of late effects. However, skin dose is not intuitive and is difficult to measure. Our objectives were to develop and evaluate a general estimation technique for skin dose based on treatment parameters. The literature on skin dose was supplemented with measurements and Monte Carlo simu...

F. Ebrahimi Tazehmahalleh, H. Esmaily, H. Gholamhosseinian, M. Layegh, N. Ebrahimi Tazehmahalleh,

Background: The goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. Materials and Methods: The study was carried out using a Nepton 10...

2015
Emine Dilek Cakmak Nina Tuncel Bora Sindir

The aim of this study was to investigate the organ doses of patients undergoing computed tomography (CT) examination using the wide bore General Electric (GE) “Light Speed RT” unit. The head, chest and pelvic regions of the Rando-phantom were scanned with 120 kV, 200 mA, and 2.5 mm slice thickness for helical and axial modes. Thermoluminescent Dosimeter (TLD) pairs were used for the dosimetry o...

2005
H. Ferreira A. Dutreix A. Bridier D. Marre J. Chavaudra H. Svensson

Background and purpose: European Society for Therapeutic Radiology and Oncology (ESTRO) has set up a Quality Assurance network for radiotherapy (EQUAL) carrying out dosimetry audit. Some of the work is done in cooperation with the IAEA. The network deals with measurements performed with mailed TLD irradiated in reference and non-reference conditions, for on-axis points in photons and electrons ...

Journal: :Medical physics 2009
Harshad Sakhalkar David Sterling John Adamovics Geoffrey Ibbott Mark Oldham

This study presents the application of the Presage/optical-CT 3D dosimetry system for relative dosimetry in the Radiologic Physics Center (RPC) Head and Neck (H&N) IMRT phantom. Performance of the system was evaluated by comparison with the "gold-standard" RPC credentialing test. A modified Presage cylindrical insert was created that extended the capability of the RPC H&N phantom to 3D dosimetr...