نتایج جستجو برای: umbilical artery
تعداد نتایج: 233997 فیلتر نتایج به سال:
Experiments on perfused segments or isolated rings of human umbilical artery showed that the magnitude of their contraction in response to bradykinin, epinephrine, or serotonin depended on the P02 of the perfusing or bathing solution. Constriction to bradykinin varied directly with the O2 tension and was greatest when the Po2 was approximately that of umbilical arterial blood during the transit...
The relationship between Doppler measurements, size and growth rate in fetal growth restriction has not been defined. We used functional linear discriminant analysis (FLDA) to investigate these parameters taking account of the difficulties inherent in exploring relationships between repeated observations from a small number of cases. In 40 fetuses with severe growth restriction, serial abdomina...
OBJECTIVE We investigated the accuracy of fetal umbilical artery Doppler to predict the risk of compromise of fetal/neonatal wellbeing in a high-risk population. METHODS Searches in MEDLINE, Embase, The Cochrane Library and Medion (from inception to March 2009) were carried out, together with hand searching of relevant journals, reference list checking of included articles and contact with ex...
OBJECTIVE We sought to provide evidence-based guidelines for utilization of Doppler studies for fetuses with intrauterine growth restriction (IUGR). METHODS Relevant documents were identified using PubMed (US National Library of Medicine, 1983 through 2011) publications, written in English, which describe the peripartum outcomes of IUGR according to Doppler assessment of umbilical arterial, m...
BACKGROUND Umbilical artery Doppler velocimetry is a routine method for fetal surveillance in high-risk pregnancy. Uterine artery Doppler seems to give comparable information, but it can be difficult to interpret as there are two arteries, which might show notching and/or increased pulsatility index (PI) as signs of increased vascular impedance. Combining the information on vascular resistance ...
An electromagnetic flow sensor was placed on the distal fetal aorta (umbilical flow fraction 78.1 +/- 1.6 SEM, %), an inflatable occluder was tied around the umbilical cord, and catheters were placed in distal branches of an umbilical artery and vein, a uterine vein, and in the amniotic cavity. An inflatalbe occluder was tied around the vagina of some of the ewes. Control values 3 days after su...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید