This paper proposes an exhaustive study about the performance analysis of Doubly Fed Induction (DFIG) under abnormal condition. Now a day, majority of power network countenance the problem of over current and grid connectivity issues. SFCL (Superconducting Fault Current Limiter), which have the competence to limit the fault current and protect the equipments from damage. SMES (Superconducting M...
Detection and removal of incipient faults in power transformer winding is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. This research article presenta a new, simple and incipient fault detection technique, which is based on symmetrical component approach. Using this protection technique, it is possible to detect minor turn-to-turn f...
Second harmonic restraint is still commonly used to discriminate fault current and transformer inrush conditions. Such approach, however, has some disadvantages and limitations. Therefore various other criteria signals for power transformer inrush discrimination have been analysed. The paper presents a new multi-criteria stabilization algorithm that employs fuzzy reasoning technique for better ...
A Matlab/Simulink implementation of a model-based diagnoses system for power transformers based on structured residuals is presented in this work. Process models for thermal behavior and moisture diffusion in paper are observers for transformer temperatures and relative water concentration in oil respectively. An experimental setup consisting of a medium voltage distribution transformer equippe...
Transformer and feeder load balancing in a distribution system reduces the risk of overloads due to load changes. The possible out of service area following the occurrence of a fault is also reduced. However, keeping in view the life expectancy of the switches, it is desirable that the number of switching operations is kept to a minimum. A new algorithm for load balancing based on fuzzy set dec...
This paper presents the envisioned next generation power distribution system architecture, the so called FREEDM system. The presented system enables the plug-andplay of distributed renewable energy resources and distributed energy storage devices, therefore functions as the “energy internet”. The recent technical developments are summarized in this paper, with emphasis on the distributed grid i...
Microgrids are a highly efficient means of embedding distributed generation sources in a power system. However, if a fault occurs inside or outside the microgrid, the microgrid should be immediately disconnected from the main grid using a static switch installed at the secondary side of the main transformer near the point of common coupling (PCC). The static switch should have a reliable module...
Fault diagnosis of power transformers have always drawn the attention among the users, without removing the transformers from the service. Thus it is necessary to detect the incipient fault of a power transformer at an early stage and diagnose properly on optimum way. Dissolved gas analyses (DGA) is widely used to detect incipient faults in oil filled power transformers. Throughout the world, d...