2010
A. Vahidian Kamyad M. H. Noori Eskandari M. Naji Midani M. Hajizadeh Saffar

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece Wise Line...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2010
Vincent Keereman Yves Fierens Tom Broux Yves De Deene Max Lonneux Stefaan Vandenberghe

UNLABELLED One of the challenges in PET/MRI is the derivation of an attenuation map to correct the PET image for attenuation. Different methods have been suggested for deriving the attenuation map from an MR image. Because the low signal intensity of cortical bone on images acquired with conventional MRI sequences makes it difficult to detect this tissue type, these methods rely on some sort of...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2015
Irene A Burger Moritz C Wurnig Anton S Becker David Kenkel Gaspar Delso Patrick Veit-Haibach Andreas Boss

UNLABELLED It was the aim of this study to implement an algorithm modifying Dixon-based MR imaging datasets for attenuation correction in hybrid PET/MR imaging with a multiacquisition variable resonance image combination (MAVRIC) sequence to reduce metal artifacts. METHODS After ethics approval, in 8 oncologic patients with dental implants data were acquired in a trimodality setup with PET/CT...

Journal: :Physics in medicine and biology 2005
Patrick L Chow Fernando R Rannou Arion F Chatziioannou

Attenuation correction is one of the important corrections required for quantitative positron emission tomography (PET). This work will compare the quantitative accuracy of attenuation correction using a simple global scale factor with traditional transmission-based methods acquired either with a small animal PET or a small animal x-ray computed tomography (CT) scanner. Two phantoms (one mouse-...

Journal: :American journal of nuclear medicine and molecular imaging 2013
Sasan Partovi Andres Kohan Chiara Gaeta Christian Rubbert Jose L Vercher-Conejero Robert S Jones James K O'Donnell Patrick Wojtylak Peter Faulhaber

The purpose of this study is to systematically evaluate the usefulness of Positron emission tomography/Magnetic resonance imaging (PET/MRI) images in a clinical setting by assessing the image quality of Positron emission tomography (PET) images using a three-segment MR attenuation correction (MRAC) versus the standard CT attenuation correction (CTAC). We prospectively studied 48 patients who ha...

2015
Abolfazl Mehranian Habib Zaidi

~250 Total manuscript: ~5620 Journal of Nuclear Medicine, published on April 9, 2015 as doi:10.2967/jnumed.115.154807 by on November 28, 2017. For personal use only. jnm.snmjournals.org Downloaded from

2011
Joseph H. Killoran Victor H Gerbaudo Marcelo Mamede Dan Ionascu Sang‐June Park Ross Berbeco

For PET/CT, fast CT acquisition time can lead to errors in attenuation correction, particularly at the lung/diaphragm interface. Gated 4D PET can reduce motion artifacts, though residual artifacts may persist depending on the CT dataset used for attenuation correction. We performed phantom studies to evaluate 4D PET images of targets near a density interface using three different methods for at...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2006
Jianbin Xiao Tim C de Wit Steven G Staelens Freek J Beekman

UNLABELLED Cardiac SPECT images are degraded by photons scattered in the thorax. Accurate correction for scatter is complicated by the nonuniform density and varied sizes of thoraxes and by the additional attenuation and scatter caused by female patients' breasts. Monte Carlo simulation is a general and accurate method for detailed modeling of scatter. Hence, for 99mTc we compared statistical r...

2015
Yukito Maeda Nobuyuki Kudomi Yasuhiro Sasakawa Toshihide Monden Koji Kato Yuka Yamamoto Nobuyuki Kawai Yoshihiro Nishiyama

BACKGROUND Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate of oxygen (CMRO2) images have facilitated understanding of the pathophysiological basis of cerebrovascular disorders. Such parametric images can be rapidly, measured within around 15 min, using positron emission tomography (PET) with sequentially administered (15)O-labeled oxygen and water. For f...

2003
Herman Schoorlemmer

New location algorithms have become available to make use of the full waveform as it is now often recorded during AT testing. A process known as Timing Strategies can lead to more accurate and reliable location. In addition to that, tools for attenuation correction and for an efficient analyses of the located events are discussed.