نتایج جستجو برای: attenuation correctionmlemscatter correctionspect

تعداد نتایج: 48983  

Journal: :The Journal of the Acoustical Society of America 2013
Jennifer B Tufts Siyuan Chen Lynne Marshall

Custom-molded earplugs (CMEPs) whose canal segments extend beyond the second bend of the ear canal can provide excellent attenuation but can sometimes be uncomfortable. Attenuation was measured for CMEPs whose canal segments were shortened in 2-mm increments. The within-subjects design permitted illustration of the form of the function relating attenuation to canal segment length for individual...

2013
Qunfeng Dong Yingle Li Jiadong Xu Mingjun Wang

Based on the forward scattering amplitude function for sand particle under the Rayleigh approximation, the calculation models of microwave attenuation and phase shift due to sand and dust particles is given in terms of lognormal size distribution. The model shows that attenuation and phase shift are found to be dependent on visibility, frequency and complex dielectric constant. Obtained results...

2012
M. S. KHAN M. GRABNER S. S. MUHAMMAD M. S. AWAN E. LEITGEB V. KVICERA R. NEBULONI

Simultaneous measurements of the liquid water content (LWC) and optical attenuation have been analyzed to predict optical attenuation caused by fog particles. Attenuation has been measured at two different wavelengths, 830 nm and 1550 nm, across co-located links. Five months measured data have been processed to assess power-law empirical models, which estimate optical attenuation from the LWC. ...

Journal: :Annals of nuclear medicine 2002
Yasuyuki Takahashi Kenya Murase Hiroshi Higashino Teruhito Mochizuki Nobutoku Motomura

PURPOSE Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. METHODS Registerion (fusion) of the X-ray CT and SPECT ima...

Journal: :The Annals of occupational hygiene 2006
Richard Neitzel Sebrina Somers Noah Seixas

The attenuation provided by a hearing protection device (HPD) in the field is usually estimated by applying a derating factor to the laboratory-determined noise reduction rating (NRR) of the HPD. However, attenuation is highly dependent on individual-specific HPD fit. Prediction of an individual's attenuation depends on the accuracy of the measurement system and the variability of attenuation o...

2006
Andrew J. Carter

S U M M A R Y The variation of frequency-dependent seismic wave attenuation with direction (attenuation anisotropy) contains additional information to that contained in velocity anisotropy. In particular, it has the potential to distinguish between different mechanisms that can cause velocity anisotropy. For example, aligned fracturing might be expected to cause measurable velocity and attenuat...

Journal: :NeuroImage 2011
Anna Manelis Mark E. Wheeler Christopher A. Paynter Lisa Storey Lynne M. Reder

The present neuroimaging study examines how repetition-related neural attenuation effects differ as a function of the perceptual similarity of the repetition and subsequent memory. One previous study (Turk-Browne et al., 2006) reported greater attenuation effects for subsequent hits than for misses. Another study (Wagner et al., 2000) found that neural attenuation is negatively correlated with ...

Journal: :Annals of nuclear medicine 2005
Jingming Bai Jun Hashimoto Koichi Ogawa Atsushi Kubo Atsushi Fukunaga Satoshi Onozuka Koichi Uchida

OBJECTIVE The aim of this study was to evaluate the effect of scatter and attenuation correction in region of interest (ROI) analysis in brain perfusion single-photon emission tomography (SPECT) and to assess the influence of selecting the reference area on semi-quantification. METHODS Ten normal subjects were enrolled and injected with 123I-iodoamphetamine to undergo simultaneous emission an...

2014
Yannick Berker Volkmar Schulz

Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany Despite promising advances, attenuation correction of PET data remains challenging in PET/MRI. Known approaches to estimating attenuation maps from PET emission data take into account only true coincidences and fail to completely determine the attenuation map...

Journal: :Medical physics 1998
P E Kinahan D W Townsend T Beyer D Sashin

In this work we demonstrate the proof of principle of CT-based attenuation correction of 3D positron emission tomography (PET) data by using scans of bone and soft tissue equivalent phantoms and scans of humans. This method of attenuation correction is intended for use in a single scanner that combines volume-imaging (3D) PET with x-ray computed tomography (CT) for the purpose of providing accu...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید