نتایج جستجو برای: background correction

تعداد نتایج: 991067  

Journal: :journal of biomedical physics and engineering 0
s a rahimi tarbiat modares university b hashemi tarbiat modares university s r mahdavi iran university of medical sciences

background: estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...

2015
D Boye O Springer F Wassmer S Scheidegger L Remonda J Berberat

BACKGROUND Velocity-encoded magnetic resonance imaging (VENC-MRI) is a commonly used technique in cardiac examinations. This technique utilizes the phase shift properties of protons moving along a magnetic field gradient. VENC-MRI offers a unique way of measuring the severity of valve regurgitation by directly quantifying the regurgitation flow volume. PURPOSE To compare flow analysis results...

2006
Martin S. Sloth

We investigate the one loop effective potential of inflation in a standard model of chaotic inflation. The leading one loop corrections to the effective inflaton potential are evaluated in the quasi de Sitter background, and we estimate the one loop correction to the two-point function of the inflaton perturbations in the Hartree approximation. In this approximation, the one loop corrections de...

Journal: Physical Treatments 2019
Farhoud Saeed Ershadi, Masoud Karimlo, Reza Vahab Kashani, Sara Rahimi,

Background: A thoracic curve degree of greater than 45° leads to thoracic hyperkyphosis, and its common treatment method is orthotic treatment. The acceptance rate of spinal orthosis depends on in-brace correction, patient`s compliance and quality of life. Objective: In this study, we aimed to compare in-brace correction, compliance and quality of life in patients with thoracic hyperkyphosis ...

2016
Erin A Paul Ana Beatriz Solana Amee Shah Wyman W Lai Anjali Chelliah

Background Phase contrast (PC) MR flow measurements are affected by phase offset errors due to local eddy currents. Performing error correction using an MR phantom prolongs each CMR study and can impede scanner workflow. Recently, a novel post-hoc nonlinear self-calibrated PC correction algorithm has been developed that can be applied to PC flow data, with equivalence to phantom correction and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید