نتایج جستجو برای: collimator angle

تعداد نتایج: 133117  

Journal: :Silampari Jurnal Pendidikan Ilmu Fisika 2022

A collimator simulator which is an accessory in radiology equipment, has been made. This was created as a learning medium to complete students' understanding studying x-rays part of electromagnetic waves. The research divided into two stages, namely the manufacture simulators and implementation teaching materials. equipped with blades that are used limit radiation field area. In this study, lam...

2002
Toru GOTO Yu GONG

The problems caused by miniaturization of the goniometer are discussed from the viewpoint of the stress error caused by mis-setting of the specimen and misalignment of the collimator and detector for the Q assembly X-ray stress analyzer using a position sensitive detector. The stress errors were calculated using a model and a simulation method. It was found that they tend to increase with the d...

2017
Kenichi Nakajima Koichi Okuda Mitsuru Momose Shinro Matsuo Chisato Kondo Masayoshi Sarai Takayuki Shibutani Masahisa Onoguchi Takeshi Shimizu A Hans Vija

IQ·SPECT (Siemens Medical Solutions) is a solution for high-sensitivity and short-time acquisition imaging of the heart for a variable angle general purpose gamma camera. It consists of a multi-focal collimator, a cardio-centric orbit and advanced iterative reconstruction, modeling the image formation physics accurately. The multi-focal collimator enables distance-dependent enlargement of the c...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 1983
A Brahme J Eenmaa S Lindbäck A Montelius P Wootton

The dose distributional properties of a p(50) Be neutron beam using a continuously variable multi-leaf collimator are presented and compared with a 6 MV photon beam. The differences in physical dose delivery between these two radiation modalities are generally insignificant for radiation therapy, and stringent comparisons of neutron and photon treatments should therefore be possible. The flexib...

2010
V.W.Y Choi E.H.W. Yum K. N. Yu

In the present paper, we propose a method to fabricate a ‘‘micro-collimator’’ with a thickness of 15mm. A commercially available PADC film with a thickness of 100mm was first chemically etched with NaOH/ethanol solution to obtain a thin PADC film. This thin PADC film was then irradiated by 5MeV a particles through a ‘‘macro-collimator’’ with a thickness of 5mm and a hole diameter of 1mm. This P...

Journal: :Epj Web of Conferences 2022

Panther is a new high-flux medium-resolution direct-geometry thermal-neutron time-of-flight spectrometer at the Institut Laue-Langevin (ILL). It designed for inelastic neutron-scattering measurements of excitations in condensed matter using single crystals, polycrystalline samples, and liquids. uses double focusing graphite or Cu monochromators, Fermi chopper, position-sensitive 3 He detectors ...

Journal: :Medical physics 1998
T LoSasso C S Chui C C Ling

The use of a multileaf collimator in the dynamic mode to perform intensity modulated radiotherapy became a reality at our institution in 1995. Unlike treatment with static fields using a multileaf collimator, there are significant dosimetric issues which must be assessed before dynamic therapy can be implemented. We have performed a series of calculations and measurements to quantify head scatt...

2011
S. Xu V. Nagarajan R. Sanishvili

In October 2009, a quad, mini-beam collimator was implemented at GM/CA CAT that allowed users to select between a 5, 10, or 20 micron mini-beam or a 300 micron scatter guard for macromolecular crystallography [1]. Initial alignment of each pinhole to the optical axis of each path through the mini-beam collimator is performed under an optical microscope using an alignment jig. Next, the pre-alig...

Journal: :Kaku igaku. The Japanese journal of nuclear medicine 2001
S Itoh N Hiramatsu A Iwata K Yoshiya S Imai

PURPOSE AND METHODS The noninvasive microsphere (NIMS) method quantifies cerebral blood flow with N-isopropyl-p-[123I]-iodoamphetamine (123I-IMP) without blood sampling of a patient, but when a fan beam collimator is used for collecting raw data in single photon emission computed tomography (SPECT), the procedure is complicated because we have to change the collimator. In phantom and clinical s...

2011
Mattijs Elschot Johannes Franciscus Wilhelmus Nijsen Alida Johanna Dam Hugo Wilhelmus Antonius Maria de Jong

BACKGROUND Scintillation camera imaging is used for treatment planning and post-treatment dosimetry in liver radioembolization (RE). In yttrium-90 (90Y) RE, scintigraphic images of technetium-99m (99mTc) are used for treatment planning, while 90Y Bremsstrahlung images are used for post-treatment dosimetry. In holmium-166 (166Ho) RE, scintigraphic images of 166Ho can be used for both treatment p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید