نتایج جستجو برای: computational phantoms

تعداد نتایج: 274208  

Journal: :journal of dentistry, tehran university of medical sciences 0
hoorieh bashizadeh fakhar elham sadat emadian razavi sepideh soheilifar mohammad javad kharazifard

objectives: the purpose of this study was to develop and test a new tool for radiographic densitometry by combining periapical films and aluminum step wedge. materials and methods: we reviewed 50 kodak e-speed intraoral films. an aluminum step wedge consisting of 16 steps was constructed. each step was 1mmx3mx10mm. the step wedge was exposed to varying exposure times, ranging from 0.05 second t...

G. Chengjun, H. Nan, H. Qing, S. Jinlu, S.B. Jiang, T. Li-wen, X. Tang, Z. Shaoxiang, Z. Xiao-lin,

Background: Accurate voxel phantom is needed for dosimetric simulation in radiation therapy for malignant tumors in female pelvic region. However, most of the existing voxel phantoms are constructed on the basis of Caucasian or non-Chinese population. Materials and Methods: A computational framework for constructing female pelvic voxel phantom for radiation dosimetry was performed base...

2016
Daniel Jimenez-Carretero Raul San Jose Estepar Mario Diaz Cacio Maria J. Ledesma-Carbayo Peter M.A. van Ooijen

The great density and structural complexity of pulmonary vessels and airways impose limitations on the generation of accurate reference standards, which are critical in training and in the validation of image processing methods for features such as pulmonary vessel segmentation or artery-vein (AV) separations. The design of synthetic computed tomography (CT) images of the lung could overcome th...

Introduction Accurate estimation of the absorbed dose in radiosensitive organs, located away from the target volume during radiotherapy, is one of the main reasons for the development of reference phantoms. The International Commission on Radiological Protection (ICRP) reference phantoms can provide a more realistic view of the human anatomy in comparison with the previously used mathematical p...

Journal: :iranian journal of radiation research 0
s. senthilkumar department of radiotherapy, madurai medical college and govt. rajaji hospital, maduari-625 020, india

background: the purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the treatment planning systems (tps) calculated values for different lung treatment dosimetery. it is compared with thermoluminescent dosimeter (tld) measurement. materials and methods: homogeneous and heterogeneous tho...

Journal: :iranian journal of medical physics 0
fatemeh lotfalizadeh department of ray-medical engineering, shiraz university, shiraz, iran mehrnoosh karimipourfard department of ray-medical engineering, shiraz university, shiraz, iran bentolhoda amanat department of physics, payame noor university, tehran, iran mehdi zehtabian department of ray-medical engineering, shiraz university, shiraz, iran

introduction based on task group no. 43 (tg-43u1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. the experimental determination of tg-43 parameters is usually performed in water-equivalent solid phantoms. the purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. materials and methods t...

Journal: :Information processing in medical imaging : proceedings of the ... conference 2007
Ying Bai Xiao Han Jerry L. Prince

Topology-preserving geometric deformable models (TGDMs) are used to segment objects that have a known topology. Their accuracy is inherently limited, however, by the resolution of the underlying computational grid. Although this can be overcome by using fine-resolution grids, both the computational cost and the size of the resulting surface increase dramatically. In order to maintain computatio...

Journal: :Medical physics 2012
S Lamart K Kim W Bolch C Lee

PURPOSE To develop a set of conversion factors from dose length product (DLP) to effective dose (E) for pediatric and adult reference individuals undergoing computed tomography (CT) examinations. METHODS This study used 12 hybrid computational phantoms representing reference pediatric and adult individuals in compliance with the International Commission on Radiological Protection (ICRP) refer...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید