نتایج جستجو برای: dental amalgam

تعداد نتایج: 162563  

Journal: :Journal of dental research 1975
J M Powers J W Farah

The modulus of elasticity of dental amalgam has been determined by analysis of creep data (OGLESBY ET AL, J Res Natl Bur Stan 72C: 203, 1968) and by ultrasonic methods (DICKSON and OGLESBY, J Dent Res 46: 1475, 1967; HALL ET AL, J Dent Res 52: 390, 1973) to be between 63,000 and 70,000 MN/m2. These values represent the instantaneous elastic compliance term when dental amalgam is treated as a vi...

2013
Robin Warwick Andrea O’Connor Brianne Lamey

BACKGROUND Amalgam that is used for dental fillings contains approximately 50% elemental mercury. During dental student training, amalgam is often removed by drilling without the use of water spray and suction, which are protective measures in preventing mercury aerosol. In this study we measured mercury vapor levels in ambient air during amalgam removal as is typically performed in dental trai...

Journal: :Journal of Occupational Medicine and Toxicology (London, England) 2008
BE Moen BE Hollund T Riise

BACKGROUND Dental assistants help the dentist in preparing material for filling teeth. Amalgam was the filling material mostly commonly used in Norway before 1980, and declined to about 5% of all fillings in 2005. Amalgam is usually an alloy of silver, copper, tin and mercury. Copper amalgam, giving particularly high exposure to mercury was used in Norway until 1994. Metallic mercury is neuroto...

2013
s. bayne P. e. Petersen D. Piper G. schmalz D. meyer

amalgam whenever possible, and environmental protection from dental materials use, including, obviously, impacts from Hg. A new general-purpose restorative material is needed as an amalgam alternative. This transition is reviewed from the point of view of international efforts at prevention, coordination of Hg management with a UNEP treaty, concern for adverse reactions from any treatments, and...

Journal: :journal of dentistry, tehran university of medical sciences 0
f. sharafeddin associate professor, department of operative dentistry, school of dentistry, shiraz university of me h. moradian post graduate student, department of pediatric dentistry, school of dentistry, shiraz university of

objective: the purpose of the present study was to assess the microleakage of composite restorations with and without a cervical amalgam base and to compare the results of dif-ferent composites and bonding agents. materials and methods: one hundred and twenty mesio-occlusal (mo) and disto-occlusal (do) class ii cavities were prepared on sixty extracted permanent premolar teeth. the teeth were r...

2011
Joachim Mutter

It was claimed by the Scientific Committee on Emerging and Newly Identified Health Risks (SCENIHR)) in a report to the EU-Commission that "....no risks of adverse systemic effects exist and the current use of dental amalgam does not pose a risk of systemic disease..." [1, available from: http://ec.europa.eu/health/ph_risk/committees/04_scenihr/docs/scenihr_o_016.pdf].SCENIHR disregarded the tox...

Journal: :Pediatrics 2012
Nancy N Maserejian Felicia L Trachtenberg Russ Hauser Sonja McKinlay Peter Shrader Mary Tavares David C Bellinger

BACKGROUND AND OBJECTIVE Resin-based dental materials may intraorally release their chemical components and bisphenol A. The New England Children's Amalgam Trial found that children randomized to amalgam had better psychosocial outcomes than those assigned to composites for posterior tooth restorations. The objective of this study was to examine whether greater exposure to dental composites is ...

Journal: :Journal of biomedical materials research 1977
J C Roberts J M Powers R G Craig

The wear of cental amalgam was studied by single- and double-pass sliding and by a silicon carbide abrasion test. A dispersed amalgam showed significantly better resistance to two-body abrasion than the spherical amalgams tested. The wear amalgam was determined by resistance to penetration and by a ductile mode of surface failure over the load range studied. Differences in the wear of amalgam a...

Journal: :international journal of occupational and environment medicine 0
smj mortazavi 1the center for research on protection against ionizing and non-ionizing radiationand medical physics department, shiraz university of medical sciences, shiraz, iran m neghab school of health and nutrition and research center for health sciences, shiraz university of medical sciences, shiraz, iran smh anoosheh student research center, school of health and nutrition, shiraz university of medical sciences, shiraz, iran n bahaeddini school of mechanics, shiraz university, shiraz, iran g mortazavi school of dentistry, shiraz university of medical sciences, shiraz, iran p neghab school of dentistry, kish international branch of shiraz university of medical sciences, kish, iran

mercury is among the most toxic nonradioactive elements which may cause toxicity even at low doses. some studies showed release of mercury from dental amalgam fillings in individuals who used mobile phone. this study was conducted to assess the effect of high-field mri on mercury release from dental amalgam filling. we studied two groups of students with identical tooth decays requiring a simil...

2010
Daniel H. Ward

Years ago, the restorative material options for the dental practitioner were limited. Direct placement materials available were either amalgam or silicate. Amalgam has long been recognized as a forgiving restorative material that works well in a variety of circumstances. Advantages of amalgam include cariostatic properties, the ability to work in varied moisture conditions, and quick bulk place...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید