نتایج جستجو برای: diaphragm deflection

تعداد نتایج: 21132  

Journal: :فصلنامه علمی پژوهشی مهندسی مکانیک جامدات واحد خمینی شهر 0
younes yousefi lecturer, engineering department, omidiyeh branch, islamic azad university, khuzestan, iran. hossein vahdanifar msc student, department of engineering shahid chamran university, khuzestan, ahwaz, iran reza shirani msc student, department of engineering shahid chamran university, khuzestan, ahwaz, iran mohamad dehghani phd student, department of mechanical engineering, yazd university , yazd ,iran

in this paper deflection and free vibration of sandwich panel is studied. the core of sandwich panels is made of hexagonal honeycomb and faces are made of two different materials of carbon fiber reinforced plastic and k-aryl/epoxy covering. the governing equations are deduced from the first order sheer deformation theory (fsdt) and they are solved using generalized differential quadrature metho...

Journal: :American journal of physiology. Gastrointestinal and liver physiology 2005
Jianmin Liu James L Puckett Torahiko Takeda Hwoon-Yong Jung Ravinder K Mittal

Esophageal distension causes simultaneous relaxation of the lower esophageal sphincter (LES) and crural diaphragm. The mechanism of crural diaphragm relaxation during esophageal distension is not well understood. We studied the motion of crural and costal diaphragm along with the motion of the distal esophagus during esophageal distension-induced relaxation of the LES and crural diaphragm. Wire...

Journal: :Journal of neurophysiology 2004
Roxanna M Webber Garrett B Stanley

Cells in the rodent barrel cortex respond to vibrissa deflection with a brief excitatory component and a longer suppressive component. The response to a given deflection is thus scaled because of suppression induced by a preceding deflection, causing the neuronal response to be linked to the temporal properties of the peripheral stimulus. A paired-deflection stimulus was used to characterize th...

2018
Hyun Woo Goo

Objective To evaluate the technical feasibility of four-dimensional (4D) CT for the functional evaluation of the pediatric diaphragm. Materials and Methods In 22 consecutive children (median age 3.5 months, age range 3 days-3 years), 4D CT was performed to assess diaphragm motion. Diaphragm abnormalities were qualitatively evaluated and diaphragm motion was quantitatively measured on 4D CT. L...

2004
Y. MADDAHI F. A. HASSANI

In practice, a robotic joint is linearly and angularly deflected when a load is applied at the endeffector. This article presents an improved method with a combination of energy methods and the concepts of differential relationships to more accurately calculate the static deflection at the end-effector. A systematic approach to deflection calculation through three different Jacobians is present...

Journal: :Paëmi Sino 2022

Objective: Agenesis of the diaphragm (AD) in adults is an extremely rare congenital malformation. To date, only a few descriptions this pathology have been published scientific literature. The article presents case detection left-sided AD 25-year-old patient operated on for diaphragmatic relaxation. Additional examination methods, including echocardiography and ultrasonography abdominal organs ...

Journal: :Annals of cardiothoracic surgery 2015
H Volkan Kara Michael J Roach Stafford S Balderson Thomas A D'Amico

The diaphragm is grasped, and as much of the anterior diaphragm as possible is pulled into a retaining clamp. This maneuver is easier to perform for the right diaphragm than the left diaphragm, owing to the risk of incorporating viscera on the left. Upon initial placement of the clamp, it is evident that all of the diaphragm that would optimally be resected cannot occur in one application. This...

2014
Willem-Jan M Schellekens Hieronymus WH van Hees Matthijs Kox Marianne Linkels Gilberto L Andrade Acuña PN Richard Dekhuijzen Gert Jan Scheffer Johannes G van der Hoeven Leo MA Heunks

INTRODUCTION Diaphragm weakness induced by prolonged mechanical ventilation may contribute to difficult weaning from the ventilator. Hypercapnia is an accepted side effect of low tidal volume mechanical ventilation, but the effects of hypercapnia on respiratory muscle function are largely unknown. The present study investigated the effect of hypercapnia on ventilator-induced diaphragm inflammat...

Journal: :Journal of applied physiology 1994
S S Margulies G T Lei G A Farkas J R Rodarte

Stress in the diaphragm, transdiaphragmatic pressure, and diaphragm shape are interrelated by a balance of forces. Using precise in vivo measurements of diaphragm shape and transdiaphragmatic pressure distribution in combination with finite-element analysis (ANSYS), we determined the direction and magnitude of stress in the passive diaphragm at relaxation volume. Lead spheres sutured along musc...

2014
Xianlong He Xueshan Yang Lizhen Zhao

Dynamic deflection measurement is an important component to the bridge loading experiment or health monitoring. Using high-precision inclinometers to test the dynamic deflection is a good method for High-Speed Railway Bridge deflection measurement in this paper, we develop a kind of precision inclinometer which comprehensives the Capacitive sensor technology and the Servo sensor technology and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید