Jarkko J. Ojala Mika K. Kapanen Simo J. Hyödynmaa Tuija K. Wigren Maunu A. Pitkänen

The accuracy of dose calculation is a key challenge in stereotactic body radiotherapy (SBRT) of the lung. We have benchmarked three photon beam dose calculation algorithms--pencil beam convolution (PBC), anisotropic analytical algorithm (AAA), and Acuros XB (AXB)--implemented in a commercial treatment planning system (TPS), Varian Eclipse. Dose distributions from full Monte Carlo (MC) simulatio...

Journal: :Radiation oncology 2018
Abdulhamid Chaikh Jarkko Ojala Catherine Khamphan Robin Garcia Jean Yves Giraud Juliette Thariat Jacques Balosso

BACKGROUND For a given prescribed dose of radiotherapy, with the successive generations of dose calculation algorithms, more monitor units (MUs) are generally needed. This is due to the implementation of successive improvements in dose calculation: better heterogeneity correction and more accurate estimation of secondary electron transport contribution. More recently, there is the possibility t...

Journal: :iranian journal of radiation research 0
f. bouzarjomehri shahid sadoughi university of medical sciences, yazd, iran m. kiani tabriz university of medical sciences, medical physics, tabriz, iran a.r. farajollahi tabriz university of medical sciences, medical physics, tabriz, iran

background: the shielding methods in radiotherapy due to delivering an accurate radiation dose to cancer tissues and avoiding unnecessary dose to normal tissues are very important. these methods include lead standard blocks, individual molding and multi leaf collimator (mlc). the mlc method is not still common in iran radiotherapy centers. individual molding is better than the lead block shield...

قرائتی, حسین, اصفهانی, مهبد, اله‌وردی, محمود, سمیعی, فرهاد, شرفی, علی‌اکبر,

In vivo dosimetry seems an appropriate method for quality assurance in radiotherapy with CO-60, which can be considered as a routine program in radiotherapy centers. In this study, entrance and exit dose in tangential fields were measured in phantom for 30 breast cancer patients by using TLD in radiotherapy section of Imam Khomeini Hospital. TLD crystals were calibrated against SSDL (Secondary...

2000
T. Kemmerer M. Lahanas N. Zamboglou

In anatomy based optimization procedures for large volume implants the calculation of dose-volume histograms (DVH) accounts for the major part of the time involved and can be as long as a few hours. This time is proportional to the number of seeds or source dwell positions required for the implant. A procedure for the calculation of brachytherapy seed dose distribution calculation employing fas...