نتایج جستجو برای: dt neutron generator
تعداد نتایج: 103915 فیلتر نتایج به سال:
The work focuses on Monte Carlo simulations for finding the optimal back scatter time-of-flight spectrometer design for concept testing at the NESSA facility at Uppsala University. The spectrometer consists of two scintillator detectors, D1 (placed in a neutron beam) and D2 (placed in front of D1), at some distance from each other. A fraction of the neutrons that impinge on D1 back scatter into...
The intensity of prompt gamma-ray was measured at various depths from chlorine-contaminated silica fume (SF) concrete slab concrete specimens using portable neutron generator-based prompt gamma-ray setup. The intensity of 6.11MeV chloride gamma-rays was measured from the chloride contaminated slab at distance of 15.25, 20.25, 25.25, 30.25 and 35.25cm from neutron target in a SF cement concrete ...
We prove the existence of regular solutions for a class of quasi-linear partial neutral functional differential equations with unbounded delay that can be described as the abstract retarded functional differential equation d dt(x(t) + F (t, xt)) = Ax(t) + G(t, xt), where A is the infinitesimal generator of a strongly continuous semigroup of bounded linear operators on a Banach space X and F , G...
We present preliminary results of measurements of the quenching factor for Na recoils in NaI(Tl) at room temperature, made at a dedicated neutron facility at the University of Sheffield. Measurements have been performed with a 2.45 MeV mono-energetic neutron generator in the energy range from 10 keV to 100 keV nuclear recoil energy. A BC501A liquid scintillator detector was used to tag neutrons...
Rossby modes (r-modes) of rotating neutron stars can be excited by the gravitomagnetic forces in coalescing binary systems. The previous study Flanagan and Racine [Phys. Rev. D 75, 044001 (2007)] showed that this kind dynamical tide (DT) induce phase shifts 0.1 rad on gravitational waveforms, which is detectable third-generation (3G) detectors. In paper, we impact DT measuring neutron-star para...
introduction:holmium-166 radionuclide is one of the most effective radionuclides used for targeted therapy with theranostic properties. one method to produce this radioisotope is via the decay of its parent (indirect method). in this study applicability of extraction chromatography (exc) for separation of no carrier added 166ho from neutron-irradiated natural dysprosium target followed by quali...
background: miniature neutron sources with high neutron flux have abundant applications in medicine, industry and researches. the most important general characteristic of miniature neutron sources is their diameter which is 3mm in average. in this research, we have surveyed and designed an am-be miniature neutron source fabrication. materials and methods: this investigation resulted in creation...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید