نتایج جستجو برای: dynamic current rate limiter

تعداد نتایج: 2020932  

2015
Rama Rao

In this paper, an application of superconducting fault current limiter (SFCL) is proposed to limit the fault current that occurs in power system, SFCL is a device that uses superconductors to instantaneously limit or reduce unanticipated electrical surges that may occur on utility distribution and transmission networks. Due to the difficulty in power network reinforcement and the interconnectio...

2011
Philippe Angot Thomas Auphan Olivier Guès

The penalization method is used to take account of obstacles in a tokamak, such as the limiter. We study a non linear hyperbolic system modelling the plasma transport in the area close to the wall. A penalization which cuts the transport term of the momentum is studied. We show numerically that this penalization creates a Dirac measure at the plasma-limiter interface which prevents us from defi...

2014
M. Vinoth kannan S. Rajanbabu

As one of the solution of the increase problem of the fault current in a power system, the superconducting fault current limiter (SFCL) has been noticed as the attractive device because it has no power loss in a normal time and can limit the fault current rapidly without additional device to detect the fault current. However, the introduction of the SFCL in a power distribution system affects t...

2018
K. Gopinath C. Baskaran

The Doubly Fed Induction Generator (DFIG) is getting wider popularity due to its ability to adapt with variable wind speed and to capture more wind energy. Though DFIG has a salient feature of the fault ride through capability, this is not sufficient to preserve the necessity of the grid code when the DFIG system is connected with the grid. To accomplish this goal, a DC resistive superconductin...

This paper proposes a novel Fault Current Limiter (FCL) for the application on distribution networks to control voltage sags at the Point of Common Coupling (PCC) during faults. This new FCL is based on series resonance including resonance transformer and series capacitor. So, by proper design of the series resonance LC tank, the fault current is limited to an acceptable level. The FCL operatio...

2014
E. Marmar M. Foord

Experiments are underway on the Alcator C Tokamak with over 1 MW of RF power injected into the plasma at a frequency of 4.6 GHz to study both heating and current drive effects. During these studies, impurity generation from limiter structures has been observed. The RF induced impurity influx is a strongly nonlinear function of net injected power. For Prf < 500 kW, only small effects are seen. A...

In this paper, the effect of number and fault current limiter(FCL) location has been investigated in order to have maximum reduction of short circuit current level in all buses in a real network. To do so, the faulty buses were identified in terms of short circuit current level by computing short circuits on the desired network. Then, while the fault current limit was modeled, its optimal locat...

ژورنال: Journal of Railway Research 2015
Mousavi G, ,

Development of the electric networks led to more interconnection in this system, therefore high level of short circuit faults flows in the networks. Many destructive damages such as instability, insulation problems and voltage mitigation can highly play unwanted influences on the system’s equipment. Using appropriate protection devices like high voltage fuses, fast switches, and such devices...

1998
R. van Buuren J. G. M. Kuerten B. J. Geurts

In this paper we numerically solve the stationary inviscid flow around an airfoil. Using the second-order explicit Runge–Kutta method in combination with the MUSCL scheme and the minmod limiter, we do not obtain a machine accurate solution. This has already been observed in literature and is explained by the non-differentiability of the minmod limiter. An analysis of the limiter shows that it i...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید