نتایج جستجو برای: ebt film dosimetry

تعداد نتایج: 98820  

Journal: :Precision radiation oncology 2023

The EBT-XD model of Gafchromic™ films has a broader optimal dynamic dose range, up to 40 Gy, compared with its predecessor models. This characteristic made suitable for high-dose applications, such as stereotactic body radiotherapy and radiosurgery, well ultra-high rate FLASH radiotherapy. purpose the current study was characterize dependence film response on linear energy transfer (LET) therap...

Journal: :iranian journal of medical physics 0
ali aghaebrahimian department of physics, isfahan university of technology, isfahan, iran mohammad hassan alamatsaz department of physics, isfahan university of technology, isfahan, iran

introduction the gamma knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. dose calculations required in the system are performed by gammaplan code; in this code, brain tissue is considered uniform. in the present study, we evaluated the effect of gamma knife system on the obtained dose through simulating a real h...

2012
Hani Alnawaf Peter K.N. Yu Martin Butson

Epson Desktop scanners have been quoted as devices which match the characteristics required for the evaluation of radiation dose exposure by radiochromic films. Specifically, models such as the 10000XL have been used successfully for image analysis and are recommended by ISP for dosimetry purposes. This note investigates and compares the scanner characteristics of three Epson desktop scanner mo...

2006
E. O ' Shea P. McCavana

Several instruments have been used to measure absorbed radiation dose under non-electronic equilibrium conditions, such as in the build-up region or near the interface between two different media, including the surface." Many of these detectors are discussed in this paper. A common method of measuring the absorbed dose distribution and electron contamination in the build-up region of high-energ...

Journal: :iranian journal of nuclear medicine 1995
h mohammadi s mehdizadeh sh derakhshan

an extensive study was undertaken to investigate on the overall film badge service performance with which occupational radiation, exposures are reported in iran, the study involved the analysis of film badges exposed to x-and gamma rays and beta particles. for test exposures, x-rays between 60 and 140 kvpco-60 gamma radiation and sr-90 beta particles were used. the actual delivered dose equival...

2001
Christopher T. Baird George Starkschall H. Helen Liu Thomas A. Buchholz Kenneth R. Hogstrom

The accuracy of the photon convolution/superposition dose algorithm employed in a commercial radiation treatment planning system was evaluated for conditions simulating tangential breast treatment. A breast phantom was fabricated from machineable wax and placed on the chest wall of an anthropomorphic phantom. Radiographic film was used to measure the dose distribution at the axial midplane of t...

2017
Davide Cusumano Maria Luisa Fumagalli Francesco Ghielmetti Linda Rossi Giuliano Grossi Raffaella Lanzarotti Laura Fariselli Elena De Martin

Gafchromic EBT3 film dosimetry in radiosurgery (RS) and hypofractionated radiotherapy (HRT) is complicated by the limited film accuracy at high fractional doses. The aim of this study is to develop and evaluate sum signal (SS) film dosimetry to increase dose resolution at high fractional doses, thus allowing for use of EBT3 for dose distribution verification of RS/HRT treatments. To characteriz...

2008
Hiroko Ohuchi Mitsuya Abe

Gafchromic XRCT radiochromic film is a self-developing high sensitivity radiochromic film product which can be used for assessment of delivered radiation doses which could match applications such as computed tomography (CT) dosimetry. The film automatically changes color upon irradiation changing from amber to dark greenish-black depending on the level of exposure. The absorption spectra of Gaf...

Journal: :Physics in medicine and biology 2001
M J Butson T Cheung P K Yu

Radiochromic film is investigated for use in dosimetry in water phantoms as opposed to solid phantoms. Investigations are performed to measure the penetration rates of water into radiochromic film and to assess the effects on optical density that this penetration causes. The effects of film orientation during irradiation in water are also tested. Results show that only a small penetration rate ...

2013
Masao Tanooka Hiroshi Doi Hideharu Miura Hiroyuki Inoue Yasue Niwa Yasuhiro Takada Masayuki Fujiwara Toshiyuki Sakai Kiyoshi Sakamoto Norihiko Kamikonya Shozo Hirota

We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral film box used for dose-distribution measurement, and a film holder for positioning a radiochromic...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید