Journal: :Physics in medicine and biology 2004
Martin J Butson Tsang Cheung Peter K N Yu

The visible absorption spectra of Radiachromic FWT-60 radiochromic film have been investigated to analyse the dosimetry characteristics of the film. The film is radiation sensitive to high absorbed doses. The visible absorption spectra of this film when exposed to photon radiation show a peak at 605 nm which is stable over the dose range of 0 Gy to 20 kGy. The radiation sensitive absorption spe...

Journal: :Physics in medicine and biology 1998
M J Butson P K Yu P E Metcalfe

Both read-out light sources and ambient light sources can produce a marked effect on coloration of radiochromic film. Fluorescent, helium neon laser, light emitting diode (LED) and incandescent read-out light sources produce an equivalent dose coloration of 660 cGy h(-1), 4.3 cGy h(-1), 1.7 cGy h(-1) and 2.6 cGy h(-1) respectively. Direct sunlight, fluorescent light and incandescent ambient lig...

Journal: :Physics in medicine and biology 2005
Martin J Butson Tsang Cheung Peter K N Yu

FWT-60 radiochromic film has been tested for colouration effects from fluorescent light sources and shown to produce a marked colouration when exposed to office fluorescent light sources showing an approximate 1 OD unit per 0.5 J m(-2) exposure to a broad ultraviolet (UV) UVA + UVB spectrum at the peak absorption wavelength. This produces a measurable and quantifiable response to UV exposure. B...

Journal: :Medical Physics 2021

Purpose The purpose of this work is to (a) demonstrate the feasibility delivering a spread-out Bragg peak (SOBP) proton beam in ultra-high dose rate (FLASH) using therapy synchrocyclotron as major step toward realizing an experimental platform for preclinical studies, and (b) evaluate response four models ionization chambers such radiation field. Methods A clinical Mevion HYPERSCAN® was adjuste...

2017
Tomohiro Shimozato Yuichi Aoyama T. Shimozato Y. Aoyama

Purpose: The aim of this study was to develop a method for the direct measurement of electron beam width and distribution at the scattering foil on the carrousel in a medical linear accelerator gantry head, which differs from an existing indirect method for measuring the focal spot size using a camera or metallic slit located outside the gantry head. Methods: The electron beam emitted by the li...

2014
Richard E. Wendt

Radiochromic film with a dye incorporated into the radiation sensitive layer [Gafchromic EBT2, Ashland, Inc.] may be digitized by a color transparency scanner, digitally processed, and calibrated so that a digital image in units of radiation absorbed dose is obtained. A transformation from raw scanner values to dose values was developed based upon a principal component analysis of the optical d...

Journal: :Medical physics 2009
Mark J Rivard Christopher S Melhus David E Wazer Raymond J Bricault

PURPOSE The AccuBoost brachytherapy system applies HDR 192Ir beams peripherally to the breast using collimating applicators. The purpose of this study was to benchmark Monte Carlo simulations of the HDR 192Ir source, to dosimetrically characterize the round applicators using established Monte Carlo simulation and radiation measurement techniques and to gather data for clinical use. METHODS Do...

2008
T Roland Y Liu N Papanikolaou C Kut C Chen J Wong R Taylor

we used a commercial radiation treatment planning system (Pinnacle, Philips Medical Systems, Andover, MA) to plan on a respiratory motion phantom. Eight plans were developed on 8 phases of the tumor cycle. The optimized dose distribution from one phase was then used in (1) to compute the 4D dose distribution for a planar film assumed to move with the tumor center. A weighted average of all the ...