نتایج جستجو برای: ebt2

تعداد نتایج: 128  

Introduction: The present study aimed to generate intensity-modulated beams with Aluminium compensating filters for a conventional telecobalt machine based on the outputs of a treatment planning system (TPS) performing forward planning and cannot simulate directly the compensating filter. Materials and Methods: In order to achieve the beam intensity modulation during treatment planning with th...

2017
Nicholas Ade F.C.P. du Plessis

The presence of metallic prostheses during external beam radiotherapy of malignancies in the pelvic region has the potential to strongly influence the dose distribution to the target and to tissue surrounded by the prostheses. This study systematically investigates the perturbation effects of unilateral titanium prosthesis on 6 and 15 MV photon beam dose distributions using Gafchromic EBT2 film...

2015
Rowen J. de Vries Steven Marsh

Internal lead shielding is utilized during superficial electron beam treatments of the head and neck, such as lip carcinoma. Methods for predicting backscattered dose include the use of empirical equations or performing physical measurements. The accuracy of these empirical equations required verification for the local electron beams. In this study, a Monte Carlo model of a Siemens Artiste lina...

2016
Elsa Y. León Marroquin José A. Herrera González Miguel A. Camacho López José E. Villarreal Barajas Olivia A. García‐Garduño

Radiochromic film has become an important tool to verify dose distributions for intensity-modulated radiotherapy (IMRT) and quality assurance (QA) procedures. A new radiochromic film model, EBT3, has recently become available, whose composition and thickness of the sensitive layer are the same as those of previous EBT2 films. However, a matte polyester layer was added to EBT3 to prevent the for...

2014
Khalid Iqbal Kent A Gifford Geoffrey Ibbott Ryan L Grant Saeed Ahmad Buzdar

This work presents a comparison of an anthropomorphic PRESAGE® dosimeter and radiochromic film measurements with a commercial treatment planning system to determine the feasibility of PRESAGE® for 3D dosimetry in breast IMRT. An anthropomorphic PRESAGE® phantom was created in the shape of a breast phantom. A five-field IMRT plan was generated with a commercially available treatment planning sys...

2013
N. Gopishankar S. Vivekanandhan G.K. Rath M.A. Laviraj S. Senthilkumaran S.S. Kale S. Thulkar R.K. Bisht V. Subramani

The purpose of this study was to validate the newly designed acrylic phantom for routine dosimetric purpose in radiotherapy. The phantom can be used to evaluate and compare the calculated dose and measured dose using film and gel dosimetric methods. In this study, a doughnut-shaped planning target volume (8.54 cm3) and inner organ at risk (0.353 cm3) were delineated for an IMRT test plan using ...

2015
Meral L. Reyhan Ting Chen Miao Zhang

Magnetic resonance (MR) imaging of Gafchromic film causes perturbation to absolute dosimetry measurements; the purpose of this work was to characterize the perturbation and develop a correction method for it. Three sets of Gafchromic EBT2 film were compared: radiation (control), radiation followed by MR imaging (RAD + B), and MR imaging followed by radiation (B + RAD). The T1-weighted and T2-we...

2017
Mohammad Javad Tahmasebibirgani Reza Maskani Mohammad Ali Behrooz Mansour Zabihzadeh Hojatollah Shahbazian Jafar Fatahiasl Nahid Chegeni

INTRODUCTION In radiotherapy, megaelectron volt (MeV) electrons are employed for treatment of superficial cancers. Magnetic fields can be used for deflection and deformation of the electron flow. A magnetic field is composed of non-uniform permanent magnets. The primary electrons are not mono-energetic and completely parallel. Calculation of electron beam deflection requires using complex mathe...

2012
Mark K.H. Chan Dora L.W. Kwong Sherry C.Y. Ng Anthony S.M. Tong Eric K.W. Tam

The dynamic movement of radiation beam in real-time tumor tracking may cause overdosing to critical organs surrounding the target. The primary objective of this study was to verify the accuracy of the 4D planning module incorporated in CyberKnife treatment planning system. The secondary objective was to evaluate the error that may occur in the case of a systematic change of motion pattern. Meas...

Hojatollah Shahbazian Jafar Fatahiasl Mansour Zabihzadeh Mohammad Ali Behrooz Mohammad Javad Tahmasebibirgani Nahid Chegeni Reza Maskani

Introduction: Photon contamination is a restriction on treatment with electron that increase dose to healthy tissue below the tumor. The aim of this study is to reduce the photon contamination using a magnet system. Materials and Methods: A mini-applicator equipped with two neodymium boron permanent magnets was designed which make it possible to adjust the d...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید