نتایج جستجو برای: field mri

تعداد نتایج: 885441  

2012
P. Marcon K. Bartusek Z. Dokoupil E. Gescheidtova

205 Diffusion MRI: Mitigation of Magnetic Field Inhomogeneities P. Marcon, K. Bartusek, Z. Dokoupil, E. Gescheidtova Department of Theoretical and Experimental Electrical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Kolejni, 2906/4., 612 00, Brno, Czech Republic, [email protected] Institute of Scientific Instruments of the ASCR v.v.i., Kral...

Journal: :Magnetic resonance in medicine 2015
Bertram J Wilm Zoltan Nagy Christoph Barmet S Johanna Vannesjo Lars Kasper Max Haeberlin Simon Gross Benjamin E Dietrich David O Brunner Thomas Schmid Klaas P Pruessmann

PURPOSE Diffusion MRI is compromised by unknown field perturbation during image encoding. The purpose of this study was to address this problem using the recently described approach of concurrent magnetic field monitoring. METHODS Magnetic field dynamics were monitored during the echo planar imaging readout of a common diffusion-weighted MRI sequence using an integrated magnetic field camera ...

2009
A. J. Lacey N. A. Thacker

For image analysis techniques to be of utility in medical diagnosis systems it is necessary to be able to perform quality control over the results they produce. Input data must conform to the assumptions within the algorithm if useful results are to be achieved. Automation of this process is essential if vision algorithms are to form components in analysis systems. In this paper we present a te...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2008
Bernd J Pichler Hans F Wehrl Martin S Judenhofer

This review concentrates on the latest advances in molecular imaging technology, including PET, MRI, and optical imaging. In PET, significant improvements in tumor detection and image resolution have been achieved by introducing new scintillation materials, iterative image reconstruction, and correction methods. These advances enabled the first clinical scanners capable of time-of-flight detect...

پایان نامه :دانشگاه آزاد اسلامی - دانشگاه آزاد اسلامی واحد یزد - دانشکده پزشکی 1392

بعد از انتخاب کودکان به وسیله نمونه گیری آسان، اطلاعات مورد نیاز مانند اطلاعات دموگرافیک، سن شروع تشنج، نوع تشنج و ... و نیز اطلاعات پاراکلینیکی مانند نتایج سی تی اسکن، mri و eeg در پرسشنامه ای محقق ساخته جمع آوری شد. مقادیر به دست آمده بعد از جمع آوری مورد تجزیه و تحلیل آماری قرار گرفت یافته ها:میان موارد سی تی اسکن مثبت و mri مثبت 3/69% بود. فراوانی نسبی غیرطبیعی بودنmri بدون تزریق مغز در هر...

2009
J. Chi F. Liu E. Weber Y. Li R. Wei W. Xu A. Trakic H. Wang S. Crozier

Introduction FDTD is widely used for EM analyses in MRI applications, due to its simplicity and efficiency in wave modelling and its ability to handle field-tissue interactions. However, contemporary MRI problems, such as high field-tissue interaction modelling requires high performance computing. Conventional CPU-based FDTD calculations offer compromised computing performance without expensive...

2008
O. R. Marrufo S. E. Solis S. S. Hidalgo A. O. Rodriguez

Introduction. The development of transceiver volume coils for high field MRI is still a very dynamic field of investigation and development. A volume coil based on the high frequency cavity resonator [1] is presented in this paper for whole-body MRI of rodents at 7 Tesla (proton frequency: 299.47 MHz). This coil design has been previously tested on phantoms at 170 MHz (4T for protons) with stan...

Journal: :Journal of magnetic resonance 2008
Vadim S Zotev Andrei N Matlashov Petr L Volegov Igor M Savukov Michelle A Espy John C Mosher John J Gomez Robert H Kraus

One of the challenges in functional brain imaging is integration of complementary imaging modalities, such as magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI). MEG, which uses highly sensitive superconducting quantum interference devices (SQUIDs) to directly measure magnetic fields of neuronal currents, cannot be combined with conventional high-field MRI in a single...

Journal: :Auris, nasus, larynx 2011
Revadi Govindaraju Rahmat Omar Raman Rajagopalan Ramli Norlisah Ng Kwan-Hoong

The higher field strength magnetic resonance imaging (MRI) such as 3 Tesla (T) and above generates noise that has potential detrimental effects on the hearing. Temporary threshold shifts following MRI examination have been reported for MRI with lower field strength. Such effect, however, have not been reported so far for a 3T MRI. We report a case that exemplifies the possible detrimental effec...

2016
Hunter C. Davis Pradeep Ramesh Aadyot Bhatnagar Audrey Lee-Gosselin John F. Barry David R. Glenn Ronald L. Walsworth Mikhail G. Shapiro

Magnetic resonance imaging (MRI) is a widely used biomedical imaging modality that derives much of its contrast from microscale magnetic field gradients in biological tissues. However, the connection between these sub-voxel field patterns and MRI contrast has not been studied experimentally. Here, we describe a new method to map subcellular magnetic fields in mammalian cells and tissues using n...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید