نتایج جستجو برای: flattening filter

تعداد نتایج: 127226  

2017
Dandan Xu Fei Jia Guowen Li Hongfei Li

In the present study, the dose verification between 6X and 6X flattening filter-free (FFF) in intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) was compared, and the advantages and disadvantages of different radiotherapy plans were evaluated. All four plans achieved comparable heterogeneity and conformity indices. For frontal tumor, VMAT demonstrated more ...

Background: This study aims to investigate radiation beam geometry of Cyberknife beam and change in dosimetric characteristics of six megavoltage (6MV) flattening filter free (FFF) beam after passing through high density cadmium free compensator alloy.Material and Methods: In this experimental study, changes in FFF beam dosimetric characteristics after passing through compensator alloy wa...

2004
Timothy C Zhu Anders Ahnesjö

The concept of in-air output ratio (Sc) was introduced to characterize how the incident photon fluence per monitor unit (or unit time for a Co-60 unit) varies with collimator settings. 2 This quantity is also called inair output factor, collimator-scatter factor, and headscatter factor. 6 The latter two names were somewhat misleading since they emphasized a single component of the output ratio....

2017
Marius Treutwein Matthias Hipp Oliver Koelbl Barbara Dobler

This study on patients with localized prostate cancer was set up to investigate valuable differences using flattened beam (FB) and flattening filter free (FFF) mode in the application of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). For ten patients, four different plans were calculated with Oncentra planning system of Elekta, using Synergy machines: IMRT ...

Journal: :Medical physics 2013
Alexandre Detappe Panagiotis Tsiamas Wilfred Ngwa Piotr Zygmanski Mike Makrigiorgos Ross Berbeco

PURPOSE The aim of this study is to quantify and to compare the dose enhancement factor from gold nanoparticles (AuNP) to tumor endothelial cells for different concentrations of AuNP, and clinical MV beam configurations. METHODS Tumor endothelial cells are modeled as slabs measuring 10 × 10 × 2 μm. A spherical AuNP is simulated on the surface of the endothelial cell, within the blood vessel. ...

2012
Stephen F. Kry Richard Popple Andrea Molineu David S. Followill

Ion recombination is approximately corrected for in the Task Group 51 protocol by Pion, which is calculated by a two-voltage measurement. This measurement approach may be a poor estimate of the true recombination, particularly if Pion is large (greater than 1.05). Concern exists that Pion in high-dose-per-pulse beams, such as flattening filter free (FFF) beams, may be unacceptably high, renderi...

Journal: :International Journal of Radiation Oncology*Biology*Physics 2015

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید