The increasing growth in power demand and the penetration of renewable distributed generations in competitive electricity market demands large and flexible capacity from the transmission grid to reduce transmission bottlenecks. The bottlenecks cause transmission congestion, reliability problems, restrict competition, and limit the maximum dispatch of low cost generations in the network. The ele...
Increased electric power consumption causes transmission lines to be driven close to or even beyond their transfer capacities resulting in overloaded lines and congestions. Flexible AC Transmission Systems (FACTS) provide an opportunity to resolve congestions by controlling power flows and voltages. Main focus in this paper lies on the Thyristor Controlled Phase Shift Transformer (TCPST). IEEE ...
One of the major causes of voltage instability is the reactive power limit of the system. Improving the system's reactive power handling capacity via Flexible AC transmission System (FACTS) devices is a remedy for prevention of voltage instability and hence voltage collapse. In this paper, the effects of SVC and STATCOM in Static Voltage Stability Margin Enhancement will be studied. AC and DC r...
1 Abstract-This paper proposed the design of wide-area robust damping (WARD) controller for multiple Flexible AC Transmission Systems (FACTS) devices to enhance the stability of power system with considering time delay of wide-area signals. Firstly, as power systems interconnect more and more to exchange large amounts, wide-area measurement system (WAMS) is widely applied to monitor and control...
In this paper a novel method for finding the fault zone on a Thyristor Controlled Series Capacitor (TCSC) incorporated transmission line is presented. The method makes use of the Support Vector Machine (SVM), used in the classification mode to distinguish between the zones, before or after the TCSC. The use of Discrete Wavelet Transform is made to prepare the features which would be given as th...
In this paper a novel method for finding the fault zone on a Thyristor Controlled Series Capacitor (TCSC) incorporated transmission line is presented. The method makes use of the Support Vector Machine (SVM), used in the classification mode to distinguish between the zones, before or after the TCSC. The use of Discrete Wavelet Transform is made to prepare the features which would be given as th...
We develop new optimization methodology for planning installation of Flexible Alternating Current Transmission System (FACTS) devices of the parallel and shunt types into large power transmission systems, which allows to delay or avoid installations of generally much more expensive power lines. Our methodology takes as an input projected economic development, expressed through a paced growth of...
An Unified Power Flow Controller (UPFC) is a typical Flexible AC Transmission System (FACTS) device playing a vital role as a stability aid for large transient disturbances in an interconnected power system.This paper deals with the design of Feedback Linearising Controller (FBLC) for UPFC.The disturbances are created in the SMIB system and the results are simulated.The results proved the supre...
Power factor correction is vital in present society. The two key benefits of power factor correction, which includes reduced power costs and higher system capacity. Implementation of Flexible AC Transmission Systems (FACTS) improves the power factor, power transfer capability and voltage stability. The shunt type of FACTS controller is used to either absorb or inject VARs into the system, there...