نتایج جستجو برای: gafchromic film film dosimetry

تعداد نتایج: 98485  

Journal: :Physics in medicine and biology 2011
Andrew Kelly Nicholas Hardcastle Peter Metcalfe Dean Cutajar Alexandra Quinn Kerwyn Foo Michael Cardoso Sheree Barlin Anatoly Rosenfeld

Curative breast radiotherapy typically leaves patients with varying degrees of cosmetic damage. One problem interfering with cosmetically acceptable breast radiotherapy is the external contour for large pendulous breasts which often results in high doses to skin folds. Thermoplastic casts are often employed to secure the breasts to maintain setup reproducibility and limit the presence of skin f...

2014
Wei Loong Jong Jeannie Hsiu Ding Wong Ngie Min Ung Kwan Hoong Ng Gwo Fuang Ho Dean L. Cutajar Anatoly B. Rosenfeld

In vivo dosimetry is important during radiotherapy to ensure the accuracy of the dose delivered to the treatment volume. A dosimeter should be characterized based on its application before it is used for in vivo dosimetry. In this study, we characterize a new MOSFET-based detector, the MOSkin detector, on surface for in vivo skin dosimetry. The advantages of the MOSkin detector are its water eq...

2015
Toshizo Katsuda Rumi Gotanda Tatsuhiro Gotanda Takuya Akagawa Nobuyoshi Tanki Tadao Kuwano Kouichi Yabunaka

Gafchromic films are used for X-ray dose measurements during diagnostic examinations and have begun to be used for three-dimensional X-ray dose measurements using the high-resolution characteristics of Gafchromic films for computed tomography. However, the problem of unevenness in Gafchromic film active layers needs to be resolved. Double exposures using X-rays are performed during therapeutic ...

2017
Andrew J. Wroe Grant McAuley Anthony V. Teran Jeannie Wong Marco Petasecca Michael Lerch James M. Slater Anatoly B. Rozenfeld

As technology continues to develop, external beam radiation therapy is being employed, with increased conformity, to treat smaller targets. As this occurs, the dosimetry methods and tools employed to quantify these fields for treatment also have to evolve to provide increased spatial resolution. The team at the University of Wollongong has developed a pixelated silicon detector prototype known ...

2008
A. A. Mowlavi F. Cupardo M. Severgnini

Theoretical and experimental studies have been applied for dosimetric parameters determination of the brachytherapy sources (1-3). Usually, Monte Carlo method has been used to define such quantities as the anisotropy dose function, the radial dose function, and the dose calculation close to the source in brachytherapy (4-6). Ir source is used widely in brachytherapy to treat localized tumors ne...

Journal: :Asian Journal Of Medical Technology 2023

Blood irradiation is done to sterilize and cease donor T-lymphocytes functionality avoid Transfusion Associated-Graft Versus Host Disease (TA-GVHD). Dose mapping the primary means of ensuring that process being conducted correctly. The aim this study measure minimum, maximum central absorbed gamma radiation dose delivered at newly customized blood equivalent phantom using a Gafchromic EBT-XD fi...

2010
Jason E. Matney Brent C. Parker Daniel W. Neck Greg Henkelmann Isaac I. Rosen

The purpose of this study was to quantify the performance and assess the utility of two different types of scanners for radiochromic EBT film dosimetry: a commercial flatbed document scanner and a widely used radiographic film scanner. We evaluated the Epson Perfection V700 Photo flatbed scanner and the Vidar VXR Dosimetry Pro Advantage scanner as measurement devices for radiochromic EBT film. ...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2011
Veerle Kersemans James Thompson Bart Cornelissen Michael Woodcock Philip D Allen Nico Buls Ruth J Muschel Mark A Hill Sean C Smart

UNLABELLED CT is widely used for anatomic referencing of PET and SPECT images of small animals but requires sufficiently high radiation doses capable of causing significant DNA damage. Therefore, we described the relationship between radiation dose, biologic damage, and image quality to determine whether CT can be used without significantly compromising radiotherapy and tumor development studie...

2002
Nobuteru NARIYAMA Yoshihito NAMITO Syuichi BAN

Introduction Recently, owing to the increase of synchrotron radiation facilities such as SPring-8, dose measurements of high-intense low-energy photons are increasingly needed for radiation protection and medical researches. For the dose measurement, tissue equivalence of dosimeter material becomes important. A radiochromic film that has sensitivity in the dose region of several Gy to 100 Gy ha...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید