نتایج جستجو برای: goldmann applanation tonometry
تعداد نتایج: 2998 فیلتر نتایج به سال:
Title: Comparison of Intraocular Pressure as Measured by Three Different Non-contact Tonometers and Goldmann Applanation Tonometer for Non-glaucomatous Subjects Authors: Seung Pil Bang ([email protected]) Chong Eun Lee ([email protected]) Yu Cheol Kim ([email protected]) Version: 3 Date: 27 Jul 2017 Author’s response to reviews: Revision Letter Manuscript Number BOPH-D-17-00287 “Comparison of Int...
THERE is no doubt that applanation tonometry gives more accurate information about the level of intra-ocular pressure than does indentation tonometry. This increased accuracy is due to the fact that applanation readings approach very closely to the levels of pressure in the undisturbed eye (Po), owing to the small volume of fluid displaced by the application of the tonometer (Goldmann, 1957). A...
AIMS To investigate an influence of mucopolysaccharidosis (MPS)- and Morbus Fabry-associated corneal opacities on intraocular pressure (IOP) measurements and to evaluate the concordance of the different tonometry methods. METHODS 25 MPS patients with or without corneal clouding, 25 Fabry patients with cornea verticillata ≥ grade 2 and 25 healthy age matched controls were prospectively include...
PURPOSE To determine the prevalence of calibration errors in Goldmann applanation tonometers at Farabi Eye Hospital. METHODS This cross-sectional study was performed on all tonometers in use at Farabi Eye Hospital. All Haag-Streit Goldmann applanation tonometers were checked according to the manufacturer's method by two independent observers and by a third observer in case of mismatched resul...
Corneal Visualization Scheimpflug Technology (CST) and Ocular Response Analyzer (ORA) measurements were carried out in 105 eyes of 69 patients with primary open-angle glaucoma. All patients had axial length (AL), central corneal thickness (CCT), intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) and eight visual fields (VF)s with the Humphrey Field Analyzer. VF progression was...
PURPOSE To compare the ocular pulse amplitude (OPA) lowering effects of preservative-free tafluprost and dorzolamide-timolol fixed combination (DTFC) using dynamic contour tonometry. METHODS In total, 66 eyes of 66 patients with normal tension glaucoma (NTG) (n = 34) or primary open angle glaucoma (POAG) (n = 32) were included. Patients were divided into two groups: the preservative-free tafl...
A prospective randomised study of 26 eyes (24 patients) following uncomplicated intracapsular cataract surgery was carried out with three groups in which different agents were used to re-form the anterior chamber: air, seven eyes; sodium hyaluronate, seven eyes; and a combination of hyaluronate plus systemic acetazolamide, 12 eyes. The intraocular pressure (IOP) was measured by Goldmann applana...
Penetrating keratoplasty is a surgical intervention that despite the progress of surgical techniques and of postoperative treatment continues to have numerous complications. Many of them, such as graft rejection, significant astigmatism, cystoid macular edema, or cataract lead to important limitations of the visual function. Glaucoma is possibly the most dangerous complication following PK, lea...
http://bjo.bmj.com/content/95/2/295.1.full.html Updated information and services can be found at: These include: References http://bjo.bmj.com/content/95/2/295.1.full.html#ref-list-1 This article cites 3 articles, 1 of which can be accessed free at: service Email alerting box at the top right corner of the online article. Receive free email alerts when new articles cite this article. Sign up in...
PURPOSE Noncontact tonometers are useful when regulations preclude use of contact tonometers by medical students and other nonophthalmologists. Our study compared the measurements by the portable, noncontact tonometer (PT100) with Goldmann applanation tonometry (GAT). METHODS This was a prospective study of 98 eyes from 98 patients. Intraocular pressure (IOP) was measured by GAT and the PT100...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید