Journal: :Turkish Journal of Electrical Engineering and Computer Sciences 2022

A new design of current mode instrumentation amplifier (CMIA) with tunable gain and low voltage operation capability is proposed in this paper, which suitable for biomedical signals processing, especially electrocardiogram (ECG). It consists a differencing transconductance (CDTA) dual z copy CDTA (DZC-CDTA). The the CMIA controlled by MOS-based resistor. main advantage its high that can be tune...

In energy supply applications for low-power sensors, there are cases where energy should be transmitted from a low-power battery to an output stage load capacitor. This paper presents an adiabatic charging circuit with a parallel switches approach that connects to a low-power battery and charges the load capacitor using a buck converter which operates in continuous conduction mode (CCM). A gate...

Journal: :international journal of mathematical modelling and computations 0
a. hussain school of chemical & materials engineering (scme) national university of sciences & technology (nust), islamabad, pakistan pakistan a. qayyum

a gas permeation model (coupling model) has been developed which has the flexibility to be used for different membrane module configurations. the aim of this work is to predict the performance of a single stage gas separation process using membranes and provide a comprehensive description of process parameters like flow rates, composition, stage cut and stream pressure. the significant feature ...

2011
Shashank Dubey Pramod Kumar Jain

This paper describes an instrumentation amplifier (INA) with three operational amplifier (op amp) topology, for biomedical applications. To achieve low offset new circuit technique is achieved by adding NMOS transistor and two phase clock scheme with a frequency of 20 KHz. With the unity gain bandwidth of 92 KHz , the open loop gain of this instrumentation amplifier is found to be 50 dB and hav...

Journal: :JCP 2011
Xianjin Zhang Yongxian Song

Input current distortion in the vicinity of input voltage zero crossing of Boost single-phase active power factor corrected rectifier in high line frequency is studied based on one cycle control method in this paper. The current loop model and input admittance model of active power correction based on one cycle control is particularly analyzed. The results point out that its equivalent power st...

Journal: :Medical engineering & physics 2001
E M Spinelli N H Martinez M A Mayosky

A biopotential amplifier for single supply operation is presented. It uses a Driven Right Leg Circuit (DRL) to drive the patient's body to a DC common mode voltage, centering biopotential signals with respect to the amplifier's input voltage range. This scheme ensures proper range operation when a single power supply is used. The circuit described is especially suited for low consumption, batte...

2007
Martin J. Burke Cedric Assambo

This paper describes the development of a very low-power pre-amplifier intended for use in pasteless-electrode recording of the human electrocardiogram. The expected input signal range is 100μV 10mV from a lead II electrode configuration. The amplifier provides a gain of 42dB in a 3dB bandwidth of 0.05Hz 2kHz with an input impedance of 280MΩ and a CMRR of greater than 80dB. Its gain and phase c...

2017
Rajesh Kumar Sanjay Tembhurne

In high-speed high-resolution analog to digital converters, comparators have a key role in quality of performance. High power consumption and delay is one of the drawbacks of these circuits which can be reduced by using suitable architectures. Many versions of comparator are proposed to achieve desirable output in sub-micron and deep sub-micron design technologies. Back to back inverter in the ...