نتایج جستجو برای: hill von mises stress

تعداد نتایج: 552295  

2016
Rui Zhang Haitao Wang Guiyin Zeng Jianqiao Li

Starting from the biomechanics principle, the three-dimensional (3D) composite model of ostrich foot locomotion system was established using dissection, medical scan modelling, reverse engineering (RE) and finite element (FE) analysis technology. Simulation calculation on the model under three groups of different loads was performed. Meanwhile, plantar pressure test on the in vitro ostrich foot...

2013
Mostafa Omran Hussein

PURPOSE This study was accomplished to assess the biomechanical state of different retaining methods of bar implant-overdenture. MATERIALS AND METHODS Two 3D finite element models were designed. The first model included implant overdenture retained by Hader-clip attachment, while the second model included two extracoronal resilient attachment (ERA) studs added distally to Hader splint bar. A ...

Journal: :Remote Sensing 2016
Giuseppe Solaro Vincenzo De Novellis Raffaele Castaldo Claudio De Luca Riccardo Lanari Michele Manunta Francesco Casu

On 16 September 2015, a Mw 8.3 interplate thrust earthquake ruptured offshore the Illapel region (Chile). Here, we perform coseismic slip fault modeling based on multi-orbit Sentinel 1-A (S1A) data. To do this, we generate ascending and descending S1A interferograms, whose combination allows us to retrieve the EW and vertical components of deformation. In particular, the EW displacement map hig...

2008
Hua Ye Cemal Basaran

A finite element simulation of stress evolution in thin metal film during electromigration is reported in this paper. The electromigration process is modeled by a coupled diffusionmechanical partial differential equations (PDEs). The PDEs are implemented with a plane strain formulation and numerically solved with the finite element (FE) method. The evolutions of hydrostatic stress, each compone...

2013
Muhammad Qasim Jae Taek Hong Raghu N. Natarajan Howard S. An

OBJECTIVE The offset connector can allow medial and lateral variability and facilitate intralaminar screw incorporation into the construct. The aim of this study was to compare the biomechanical characteristics of C7 intralaminar screw constructs with and without offset connector using a three dimensional finite element model of a C6-7 cervical spine segment. METHODS Finite element models rep...

2015
Mitsuaki Noda Yasuhiro Saegusa Masayasu Takahashi Daichi Tezuka Kazuhiko Adachi Kazuya Naoi

BACKGROUND Several factors are known to influence osseous union of femoral neck fractures. Numerous clinical studies have reported different results, hence with different recommendations regarding treatment of Pauwels III fractures: femoral neck fractures with a more vertically oriented fracture line. The current study aimed to analyze biomechanically whether this fracture poses a higher risk o...

2010

INTRODUCTION: Transforaminal lumbar interbody fusion (TLIF) with transpedicle screw (TPS) fixation was accepted as a minimally invasive surgery to treat degenerative disc disease for decompression and maintaining stability. According to previous researches, spinal fusion using bilateral TPS (BTPS) fixation with single or paired cages could sufficiently maintain vertebral stabilities, but the un...

The purpose of this paper is to introduce a new estimation method for estimating the Archimedean copula dependence parameter in the non-parametric setting. The estimation of the dependence parameter has been selected as the value that minimizes the Cramér-von-Mises distance which measures the distance between Empirical Bernstein Kendall distribution function and true Kendall distribution functi...

2009
Darryl D. D’Lima Peter C. Chen Clifford W. Colwell Jr.

Osteochondral grafting for cartilage lesions is an attractive surgical procedure; however, the clinical results have not always been successful. Surgical recommendations differ with respect to donor site and graft placement technique. No clear biomechanical analysis of these surgical options has been reported. We hypothesized that differences in graft placement, graft biomechanical properties, ...

2017
Zhang Xing Ling Song Chen Wei Peng Ling Jian Chen

PURPOSE A mathematical simulation of stress distribution around orbital implants was used to determine which length and diameter of implants would be best to dissipate stress. METHODS An integrated system for computed tomography data was utilized to create a 3-dimensional model of craniofacial structures. The model simulated implants placed in the 7, 11, and 12 o'clock positions of the orbita...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید