نتایج جستجو برای: joint prostheses
تعداد نتایج: 199162 فیلتر نتایج به سال:
The performance of total ankle replacements (TARs) have not been comparable to those of the other major joints of the lower extremity. The aim of this work was to develop a new simulator test to compare the wear of a new mobile bearing TAR (Mobility) with one with a good clinical history, the Buechel Pappas, using kinematic inputs derived from the literature. The wear rate for the Mobility comp...
When a metallic implant is in contact with human tissues, the organism reacts and a corrosion process starts. Consequently, we might observe liberation of metallic debris and wear. Our purpose is to measure the contamination and the migration of these metallic elements in the surrounding tissues of the implant. Two types of samples have been studied. First type is sample taken on post-mortem ti...
Polyethylene wear is a significant clinical problem in total knee arthroplasty (TKA). Although the tribology of joint replacement has consequently become an area of significant research, the effect of joint fluid on lubrication has been largely overlooked in the replaced joint. One factor that affects the tribology of metal on polyethylene articulation in joint prostheses is mechanical properti...
The first 25 consecutive patients with high occlusal plane angulation, dysfunction, and pain who were treated with temporomandibular joint (TMJ) total joint prostheses and simultaneous maxillomandibular counterclockwise rotation were evaluated before surgery (T1), immediately after surgery (T2), and at the longest follow-up (T3) for surgical movements and long-term stability. Subjective ratings...
Advances in surgical procedure, prosthesis design, and biomaterials performance have considerably increased the longevity of total joint replacements. Preoperative planning is another step in joint replacement that may have the potential to improve clinical outcome for the individual patient, but has remained relatively consistent for a long time. One means of advancing this aspect of joint rep...
Whereas detailed information on Syme prostheses prior to the turn of the 20th century is not readily to be had, the catalogs issued by limb manufacturers in the early 1900's seem invariably to include a description of a prosthesis for the Syme stump. Of many different designs offered, some used articulated ankles (if space were available below the stump and socket), some used rubber feet withou...
Today, commercially available ankle-foot prostheses are completely passive, and consequently, their mechanical properties remain fixed with walking speed and terrain. Conversely, normal human ankle stiffness varies within each gait cycle and also with walking speed [1][2][3]. Furthermore, some studies have indicated that one of the main functions of the human ankle is to provide adequate energy...
In the last years, several materials and design have been assessed in an attempt to improve mechanical performance of temporomandibular joint total replacement (TMJ TJR) prostheses. However, wear TMJ TJR condyle polymer-based fossa component during loading sliding movements. That promotes release debris risks toxicity surrounding tissues. The purpose this study was perform a narrative literatur...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید