نتایج جستجو برای: liquid scintillation detector
تعداد نتایج: 275743 فیلتر نتایج به سال:
LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time projection chamber (LXeTPC) for imaging cosmic γ–rays in the energy band of 0.2-20 MeV. The detector, with 400 cm 2 area and 7 cm drift gap, is filled with high purity LXe. Both ionization and scintillation light signals are detected to measure the energy deposits and the three spatial coordinates of individual γ–ray inte...
BC-501 is a liquid scintillation detector sensitive to both neutrons and gamma rays. As these produce slightly different signals in the detector, they can be discriminated based on their pulse shape (Pulse Shape Discrimination, PSD). This paper reports on results obtained with several PSD techniques and compares them with a method based on artificial neural networks (NN) developed for this appl...
The WARP programme is a graded programme intended to search for cold Dark Matter in the form of WIMP’s. These particles may produce via weak interactions nuclear recoils in the energy range 10 − 100 keV . A cryogenic noble liquid like argon, already used in the realization of very large detector, permits the simultaneous detection of both ionisation and scintillation induced by an interaction, ...
discussed, and he points out that merely because a disease is found to be familial in incidence does not mean it is hereditarily transmitted; leprosy, for instance, was long held to be a hereditary disease, and a law was actually proposed in the Norwegian Parliament forbidding the marriage of lepers for that reason. It was only with the discovery of the leprosy bacillus by Hansen that the true ...
background: high level radiation areas have been recognized on various parts of the earth. mahallat hot spring region is one of these areas. study of exposure in these areas can be helpful in investigating the effects of ionizing radiation. internal and external exposure to the staff was studied. materials and methods: used materials and instruments include: rss-112 ionizing chamber for environ...
dispersive liquid-liquid microextraction method (dllme) combined with high-performance liquid chromatography-ultraviolet detection (hplc-uv) was used to determine thiamine (b1), nicotinamide (b3) and pyridoxine (b6) in sour cherry juice. this method was rapid, simple and sensitive. separation was accomplished using a c18 column. the optimum chromatographic conditions were found to be: mobile ph...
The use of liquid helium and neon as scintillators for neutrino detection is investigated. Several unique properties of these cryogens make them promising candidates for real-time solar neutrino spectroscopy: large ultraviolet scintillation yields from ionizing radiation, transparency to their own scintillation light, and low levels of radioactive impurities. When neutrinos scatter from electro...
Given that the technology of choice for 2) is LS, the first generation plan for 1) was a piled array of longitudinal logs where the event vertex within a log is inferred from differential times of flight of signals observed at the ends of the log. In the second generation strategy true 3-d event localization could be achieved directly and digitally. In a “scintillation lattice chamber” . Two ba...
The objective of this work is to develop procedures for internal monitoring of (18)F to be applied in cases of possible incorporation of fluoride and (18)FDG, using in vivo and in vitro methods of measurements. The Na I (Tl) 8" x 4" scintillation detector installed at IRD-Whole Body Counter was calibrated for measurements with a whole body anthropomorphic phantom, simulating homogeneous distrib...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید